net: phy: dp83867: perform soft reset and retain established link
Current logic is performing hard reset and causing the programmed registers to be wiped out. as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf 8.6.26 Control Register (CTRL) do SW_RESTART to perform a reset not including the registers, If performed when link is already present, it will drop the link and trigger re-auto negotiation. Signed-off-by: Praneeth Bajjuri <praneeth@ti.com> Signed-off-by: Geet Modi <geet.modi@ti.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
232e3683b4
commit
da9ef50f54
|
@ -826,16 +826,12 @@ static int dp83867_phy_reset(struct phy_device *phydev)
|
|||
{
|
||||
int err;
|
||||
|
||||
err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESET);
|
||||
err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESTART);
|
||||
if (err < 0)
|
||||
return err;
|
||||
|
||||
usleep_range(10, 20);
|
||||
|
||||
/* After reset FORCE_LINK_GOOD bit is set. Although the
|
||||
* default value should be unset. Disable FORCE_LINK_GOOD
|
||||
* for the phy to work properly.
|
||||
*/
|
||||
return phy_modify(phydev, MII_DP83867_PHYCTRL,
|
||||
DP83867_PHYCR_FORCE_LINK_GOOD, 0);
|
||||
}
|
||||
|
|