Documentation: broadcom-bcmgenet: add better clocks documentation

Document the required "clocks" phandles and their corresponding
"clock-names" properties for the two clocks used by the GENET hardware
block ("enet" and "enet-wol").

CC: Mark Rutland <mark.rutland@arm.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Florian Fainelli 2014-02-14 15:21:42 -08:00 committed by David S. Miller
parent a11607f5a1
commit d94b27c8b6
1 changed files with 5 additions and 2 deletions

View File

@ -14,8 +14,11 @@ Required properties:
- size-cells: should be 1
Optional properties:
- clocks: When provided, must be two cells, first one is the main GENET clock
and the second cell is the Genet Wake-on-LAN clock.
- clocks: When provided, must be two phandles to the functional clocks nodes
of the GENET block. The first phandle is the main GENET clock used during
normal operation, while the second phandle is the Wake-on-LAN clock.
- clock-names: When provided, names of the functional clock phandles, first
name should be "enet" and second should be "enet-wol".
- phy-handle: A phandle to a phy node defining the PHY address (as the reg
property, a single integer), used to describe configurations where a PHY