staging: comedi: pcmuio: fix types of some private data variables
The 'enabled_mask' is a bit mask of the channels that are enabled for interrupt detection and should be an unsigned int. The 'stop_count' is a >= 0 value that is set by the unsigned int cmd->stop_arg. Make it an unsigned int. The 'active' and 'continuous' members are flags. Make them unsigned int bit-fields to save a bit of space. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Cc: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
25ad998892
commit
d5f81755d6
|
@ -130,10 +130,10 @@ static const struct pcmuio_board pcmuio_boards[] = {
|
|||
struct pcmuio_asic {
|
||||
spinlock_t pagelock; /* protects the page registers */
|
||||
spinlock_t spinlock; /* protects member variables */
|
||||
int enabled_mask;
|
||||
int active;
|
||||
int stop_count;
|
||||
int continuous;
|
||||
unsigned int enabled_mask;
|
||||
unsigned int stop_count;
|
||||
unsigned int active:1;
|
||||
unsigned int continuous:1;
|
||||
};
|
||||
|
||||