dt-bindings: mvebu-uart: update documentation with extended UART

Update the device tree binding documentation for the Marvell EBU UART,
in order to allow describing the extended UART IP block, in addition to
the already supported standard UART IP. This requires adding a new
compatible string, the introduction of a clocks property, and extensions
to the interrupts property.

Signed-off-by: Miquel Raynal <miquel.raynal@free-electrons.com>
Reviewed-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Miquel Raynal 2017-12-07 11:12:59 +01:00 committed by Greg Kroah-Hartman
parent 5c3055393f
commit d160c34134
1 changed files with 45 additions and 5 deletions

View File

@ -1,13 +1,53 @@
* Marvell UART : Non standard UART used in some of Marvell EBU SoCs (e.g., Armada-3700)
* Marvell UART : Non standard UART used in some of Marvell EBU SoCs
e.g., Armada-3700.
Required properties:
- compatible: "marvell,armada-3700-uart"
- compatible:
- "marvell,armada-3700-uart" for the standard variant of the UART
(32 bytes FIFO, no DMA, level interrupts, 8-bit access to the
FIFO, baudrate limited to 230400).
- "marvell,armada-3700-uart-ext" for the extended variant of the
UART (128 bytes FIFO, DMA, front interrupts, 8-bit or 32-bit
accesses to the FIFO, baudrate unlimited by the dividers).
- reg: offset and length of the register set for the device.
- interrupts: device interrupt
- clocks: UART reference clock used to derive the baudrate. If no clock
is provided (possible only with the "marvell,armada-3700-uart"
compatible string for backward compatibility), it will only work
if the baudrate was initialized by the bootloader and no baudrate
change will then be possible.
- interrupts:
- Must contain three elements for the standard variant of the IP
(marvell,armada-3700-uart): "uart-sum", "uart-tx" and "uart-rx",
respectively the UART sum interrupt, the UART TX interrupt and
UART RX interrupt. A corresponding interrupt-names property must
be defined.
- Must contain two elements for the extended variant of the IP
(marvell,armada-3700-uart-ext): "uart-tx" and "uart-rx",
respectively the UART TX interrupt and the UART RX interrupt. A
corresponding interrupts-names property must be defined.
- For backward compatibility reasons, a single element interrupts
property is also supported for the standard variant of the IP,
containing only the UART sum interrupt. This form is deprecated
and should no longer be used.
Example:
serial@12000 {
uart0: serial@12000 {
compatible = "marvell,armada-3700-uart";
reg = <0x12000 0x200>;
interrupts = <43>;
clocks = <&xtalclk>;
interrupts =
<GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>,
<GIC_SPI 12 IRQ_TYPE_LEVEL_HIGH>,
<GIC_SPI 13 IRQ_TYPE_LEVEL_HIGH>;
interrupt-names = "uart-sum", "uart-tx", "uart-rx";
};
uart1: serial@12200 {
compatible = "marvell,armada-3700-uart-ext";
reg = <0x12200 0x30>;
clocks = <&xtalclk>;
interrupts =
<GIC_SPI 30 IRQ_TYPE_EDGE_RISING>,
<GIC_SPI 31 IRQ_TYPE_EDGE_RISING>;
interrupt-names = "uart-tx", "uart-rx";
};