clk: si5351: Rename internal plls to avoid name collisions
This drivers probe fails due to a clock name collision if a clock named 'plla' or 'pllb' is already registered when registering this drivers internal plls. Fix it by renaming internal plls to avoid name collisions. Cc: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com> Cc: Rabeeh Khoury <rabeeh@solid-run.com> Signed-off-by: Sergej Sawazki <sergej@taudac.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
This commit is contained in:
parent
b26ff127c5
commit
cdba9a4fb0
|
@ -72,7 +72,7 @@ static const char * const si5351_input_names[] = {
|
|||
"xtal", "clkin"
|
||||
};
|
||||
static const char * const si5351_pll_names[] = {
|
||||
"plla", "pllb", "vxco"
|
||||
"si5351_plla", "si5351_pllb", "si5351_vxco"
|
||||
};
|
||||
static const char * const si5351_msynth_names[] = {
|
||||
"ms0", "ms1", "ms2", "ms3", "ms4", "ms5", "ms6", "ms7"
|
||||
|
|