arm64: add SIGSYS siginfo for compat task
SIGSYS is primarily used in secure computing to notify tracer of syscall events. This patch allows signal handler on compat task to get correct information with SA_SIGINFO specified when this signal is delivered. Reviewed-by: Kees Cook <keescook@chromium.org> Signed-off-by: AKASHI Takahiro <takahiro.akashi@linaro.org> Signed-off-by: Will Deacon <will.deacon@arm.com>
This commit is contained in:
parent
e185fab7e1
commit
cc5e9097c9
|
@ -205,6 +205,13 @@ typedef struct compat_siginfo {
|
|||
compat_long_t _band; /* POLL_IN, POLL_OUT, POLL_MSG */
|
||||
int _fd;
|
||||
} _sigpoll;
|
||||
|
||||
/* SIGSYS */
|
||||
struct {
|
||||
compat_uptr_t _call_addr; /* calling user insn */
|
||||
int _syscall; /* triggering system call number */
|
||||
compat_uint_t _arch; /* AUDIT_ARCH_* of syscall */
|
||||
} _sigsys;
|
||||
} _sifields;
|
||||
} compat_siginfo_t;
|
||||
|
||||
|
|
|
@ -186,6 +186,12 @@ int copy_siginfo_to_user32(compat_siginfo_t __user *to, const siginfo_t *from)
|
|||
err |= __put_user(from->si_uid, &to->si_uid);
|
||||
err |= __put_user((compat_uptr_t)(unsigned long)from->si_ptr, &to->si_ptr);
|
||||
break;
|
||||
case __SI_SYS:
|
||||
err |= __put_user((compat_uptr_t)(unsigned long)
|
||||
from->si_call_addr, &to->si_call_addr);
|
||||
err |= __put_user(from->si_syscall, &to->si_syscall);
|
||||
err |= __put_user(from->si_arch, &to->si_arch);
|
||||
break;
|
||||
default: /* this is just in case for now ... */
|
||||
err |= __put_user(from->si_pid, &to->si_pid);
|
||||
err |= __put_user(from->si_uid, &to->si_uid);
|
||||
|
|