iio: adc: max9611: Fix attribute measure unit
The power and current "shunt-resistor" attribute's 'show' function displays the resistor value in milli-Ohms, while the ABI description specifies it should be displayed in Ohms. Fix it. Reported-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Jacopo Mondi <jacopo+renesas@jmondi.org> Tested-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
5ba5b437ef
commit
c545171968
|
@ -438,10 +438,10 @@ static ssize_t max9611_shunt_resistor_show(struct device *dev,
|
|||
struct max9611_dev *max9611 = iio_priv(dev_to_iio_dev(dev));
|
||||
unsigned int i, r;
|
||||
|
||||
i = max9611->shunt_resistor_uohm / 1000;
|
||||
r = max9611->shunt_resistor_uohm % 1000;
|
||||
i = max9611->shunt_resistor_uohm / 1000000;
|
||||
r = max9611->shunt_resistor_uohm % 1000000;
|
||||
|
||||
return sprintf(buf, "%u.%03u\n", i, r);
|
||||
return sprintf(buf, "%u.%06u\n", i, r);
|
||||
}
|
||||
|
||||
static IIO_DEVICE_ATTR(in_power_shunt_resistor, 0444,
|
||||
|
|
Loading…
Reference in New Issue