[SCSI] mpt2sas: Excessive log info causes sas iounit page time out
Inhibit 0x3117 loginfos - during cable pull, there are too many printks going to the syslog, this is have impact on how fast the interrupt routine can handle keeping up with command completions; this was the root cause to the config pages timeouts. Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
parent
62727a7ba4
commit
be9e8cd75c
|
@ -440,6 +440,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTER *ioc , u32 log_info)
|
|||
if (sas_loginfo.dw.bus_type != 3 /*SAS*/)
|
||||
return;
|
||||
|
||||
/* each nexus loss loginfo */
|
||||
if (log_info == 0x31170000)
|
||||
return;
|
||||
|
||||
/* eat the loginfos associated with task aborts */
|
||||
if (ioc->ignore_loginfos && (log_info == 30050000 || log_info ==
|
||||
0x31140000 || log_info == 0x31130000))
|
||||
|
|
|
@ -2767,6 +2767,10 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,
|
|||
char *desc_ioc_state = NULL;
|
||||
char *desc_scsi_status = NULL;
|
||||
char *desc_scsi_state = ioc->tmp_string;
|
||||
u32 log_info = le32_to_cpu(mpi_reply->IOCLogInfo);
|
||||
|
||||
if (log_info == 0x31170000)
|
||||
return;
|
||||
|
||||
switch (ioc_status) {
|
||||
case MPI2_IOCSTATUS_SUCCESS:
|
||||
|
|
Loading…
Reference in New Issue