iio: hid-sensors: Inclinometer 3D: adjust scale and offset
Using units and unit exponent to calculate scale which is compliant to IIO ABI. Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
92463fdab5
commit
be8e48d67e
|
@ -42,6 +42,10 @@ struct incl_3d_state {
|
|||
struct hid_sensor_common common_attributes;
|
||||
struct hid_sensor_hub_attribute_info incl[INCLI_3D_CHANNEL_MAX];
|
||||
u32 incl_val[INCLI_3D_CHANNEL_MAX];
|
||||
int scale_pre_decml;
|
||||
int scale_post_decml;
|
||||
int scale_precision;
|
||||
int value_offset;
|
||||
};
|
||||
|
||||
static const u32 incl_3d_addresses[INCLI_3D_CHANNEL_MAX] = {
|
||||
|
@ -125,12 +129,12 @@ static int incl_3d_read_raw(struct iio_dev *indio_dev,
|
|||
ret_type = IIO_VAL_INT;
|
||||
break;
|
||||
case IIO_CHAN_INFO_SCALE:
|
||||
*val = incl_state->incl[CHANNEL_SCAN_INDEX_X].units;
|
||||
ret_type = IIO_VAL_INT;
|
||||
*val = incl_state->scale_pre_decml;
|
||||
*val2 = incl_state->scale_post_decml;
|
||||
ret_type = incl_state->scale_precision;
|
||||
break;
|
||||
case IIO_CHAN_INFO_OFFSET:
|
||||
*val = hid_sensor_convert_exponent(
|
||||
incl_state->incl[CHANNEL_SCAN_INDEX_X].unit_expo);
|
||||
*val = incl_state->value_offset;
|
||||
ret_type = IIO_VAL_INT;
|
||||
break;
|
||||
case IIO_CHAN_INFO_SAMP_FREQ:
|
||||
|
@ -279,6 +283,11 @@ static int incl_3d_parse_report(struct platform_device *pdev,
|
|||
st->incl[1].index, st->incl[1].report_id,
|
||||
st->incl[2].index, st->incl[2].report_id);
|
||||
|
||||
st->scale_precision = hid_sensor_format_scale(
|
||||
HID_USAGE_SENSOR_INCLINOMETER_3D,
|
||||
&st->incl[CHANNEL_SCAN_INDEX_X],
|
||||
&st->scale_pre_decml, &st->scale_post_decml);
|
||||
|
||||
/* Set Sensitivity field ids, when there is no individual modifier */
|
||||
if (st->common_attributes.sensitivity.index < 0) {
|
||||
sensor_hub_input_get_attribute_info(hsdev,
|
||||
|
|