clocksource/drivers/dbx500: Demote dbx500 PRCMU clocksource

Demote the DBx500 PRCMU clocksource to quality 100 and
mark it as NONSTOP so it will still be used for
timekeeping across suspend/resume.

The Nomadik MTU timer which has higher precision will
be used when the system is up and running, thanks to
the recent changes properly utilizing the suspend
clocksources.

This was discussed back in 2011 when the driver was
written, but the infrastructure was not available
upstream to use this timer properly. Now the
infrastructure is there, so let's finalize the work.

Cc: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Reviewed-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
This commit is contained in:
Linus Walleij 2018-11-15 14:32:02 +01:00 committed by Daniel Lezcano
parent 30a85eb643
commit bc0750e464
1 changed files with 2 additions and 2 deletions

View File

@ -46,10 +46,10 @@ static u64 notrace clksrc_dbx500_prcmu_read(struct clocksource *cs)
static struct clocksource clocksource_dbx500_prcmu = {
.name = "dbx500-prcmu-timer",
.rating = 300,
.rating = 100,
.read = clksrc_dbx500_prcmu_read,
.mask = CLOCKSOURCE_MASK(32),
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
.flags = CLOCK_SOURCE_IS_CONTINUOUS | CLOCK_SOURCE_SUSPEND_NONSTOP,
};
#ifdef CONFIG_CLKSRC_DBX500_PRCMU_SCHED_CLOCK