thermal: cpu_cooling: Pass 'cpufreq_dev' to get_property()
We already know the value of 'cpufreq_dev->max_level' and so there is no need calculating that once again. For this, we need to send 'cpufreq_dev' to get_property(). Make all necessary changes for this change. Because cpufreq_cooling_get_level() doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of cpufreq_cooling_devices to get cooling device for the cpu number passed to it. This also makes it robust to return levels only for the CPU registered via a cooling device. We don't have to support anything that isn't registered yet. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
2479bb6443
commit
b9f8b41603
|
@ -118,7 +118,7 @@ enum cpufreq_cooling_property {
|
|||
|
||||
/**
|
||||
* get_property - fetch a property of interest for a given cpu.
|
||||
* @cpu: cpu for which the property is required
|
||||
* @cpufreq_dev: cpufreq_dev for which the property is required
|
||||
* @input: query parameter
|
||||
* @output: query return
|
||||
* @property: type of query (frequency, level)
|
||||
|
@ -135,20 +135,20 @@ enum cpufreq_cooling_property {
|
|||
*
|
||||
* Return: 0 on success, -EINVAL when invalid parameters are passed.
|
||||
*/
|
||||
static int get_property(unsigned int cpu, unsigned long input,
|
||||
unsigned int *output,
|
||||
static int get_property(struct cpufreq_cooling_device *cpufreq_dev,
|
||||
unsigned long input, unsigned int *output,
|
||||
enum cpufreq_cooling_property property)
|
||||
{
|
||||
int i;
|
||||
unsigned long max_level = 0, level = 0;
|
||||
unsigned long level = 0;
|
||||
unsigned int freq = CPUFREQ_ENTRY_INVALID;
|
||||
int descend = -1;
|
||||
struct cpufreq_frequency_table *pos, *table =
|
||||
cpufreq_frequency_get_table(cpu);
|
||||
struct cpufreq_frequency_table *pos, *table;
|
||||
|
||||
if (!output)
|
||||
return -EINVAL;
|
||||
|
||||
table = cpufreq_frequency_get_table(cpumask_first(&cpufreq_dev->allowed_cpus));
|
||||
if (!table)
|
||||
return -EINVAL;
|
||||
|
||||
|
@ -162,18 +162,10 @@ static int get_property(unsigned int cpu, unsigned long input,
|
|||
descend = freq > pos->frequency;
|
||||
|
||||
freq = pos->frequency;
|
||||
max_level++;
|
||||
}
|
||||
|
||||
/* No valid cpu frequency entry */
|
||||
if (max_level == 0)
|
||||
return -EINVAL;
|
||||
|
||||
/* max_level is an index, not a counter */
|
||||
max_level--;
|
||||
|
||||
if (property == GET_FREQ)
|
||||
level = descend ? input : (max_level - input);
|
||||
level = descend ? input : (cpufreq_dev->max_level - input);
|
||||
|
||||
i = 0;
|
||||
cpufreq_for_each_valid_entry(pos, table) {
|
||||
|
@ -186,7 +178,7 @@ static int get_property(unsigned int cpu, unsigned long input,
|
|||
|
||||
if (property == GET_LEVEL && (unsigned int)input == freq) {
|
||||
/* get level by frequency */
|
||||
*output = descend ? i : (max_level - i);
|
||||
*output = descend ? i : (cpufreq_dev->max_level - i);
|
||||
return 0;
|
||||
}
|
||||
if (property == GET_FREQ && level == i) {
|
||||
|
@ -213,12 +205,25 @@ static int get_property(unsigned int cpu, unsigned long input,
|
|||
*/
|
||||
unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
|
||||
{
|
||||
unsigned int val;
|
||||
struct cpufreq_cooling_device *cpufreq_dev;
|
||||
|
||||
if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
|
||||
return THERMAL_CSTATE_INVALID;
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
|
||||
if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
|
||||
unsigned int val;
|
||||
|
||||
return (unsigned long)val;
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
if (get_property(cpufreq_dev, (unsigned long)freq, &val,
|
||||
GET_LEVEL))
|
||||
return THERMAL_CSTATE_INVALID;
|
||||
|
||||
return (unsigned long)val;
|
||||
}
|
||||
}
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
|
||||
return THERMAL_CSTATE_INVALID;
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
|
||||
|
||||
|
@ -323,7 +328,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
|||
if (cpufreq_device->cpufreq_state == state)
|
||||
return 0;
|
||||
|
||||
ret = get_property(cpu, state, &clip_freq, GET_FREQ);
|
||||
ret = get_property(cpufreq_device, state, &clip_freq, GET_FREQ);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
|
@ -381,8 +386,7 @@ __cpufreq_cooling_register(struct device_node *np,
|
|||
if (!cpufreq_dev)
|
||||
return ERR_PTR(-ENOMEM);
|
||||
|
||||
ret = get_property(cpumask_any(clip_cpus), 0, &cpufreq_dev->cpufreq_val,
|
||||
GET_FREQ);
|
||||
ret = get_property(cpufreq_dev, 0, &cpufreq_dev->cpufreq_val, GET_FREQ);
|
||||
if (ret) {
|
||||
pr_err("%s: Failed to get frequency: %d", __func__, ret);
|
||||
cool_dev = ERR_PTR(ret);
|
||||
|
|
Loading…