PM / OPP: dt-bindings: Make "opp-hz" optional for power domains
The "opp-hz" property is not relevant across all the devices that use the OPP tables now. For example, for a power domain a frequency value wouldn't mean anything. Though they must have another property, which may be implementation defined, which uniquely identifies the OPP nodes. Make "opp-hz" optional for such devices. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org> Reviewed-by: Rob Herring <robh@kernel.org>
This commit is contained in:
parent
f05fededbb
commit
b89469bdf0
|
@ -82,7 +82,10 @@ This defines voltage-current-frequency combinations along with other related
|
|||
properties.
|
||||
|
||||
Required properties:
|
||||
- opp-hz: Frequency in Hz, expressed as a 64-bit big-endian integer.
|
||||
- opp-hz: Frequency in Hz, expressed as a 64-bit big-endian integer. This is a
|
||||
required property for all device nodes but devices like power domains. The
|
||||
power domain nodes must have another (implementation dependent) property which
|
||||
uniquely identifies the OPP nodes.
|
||||
|
||||
Optional properties:
|
||||
- opp-microvolt: voltage in micro Volts.
|
||||
|
|
Loading…
Reference in New Issue