[PATCH] hpet: fix division by zero in HPET_INFO

Fix a division by zero that happened when the HPET_INFO ioctl was called
before a timer frequency had been set.

Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: Bob Picco <bob.picco@hp.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
Clemens Ladisch 2005-10-30 15:03:38 -08:00 committed by Linus Torvalds
parent 8e8505be9c
commit af95eade68
1 changed files with 5 additions and 2 deletions

View File

@ -494,8 +494,11 @@ hpet_ioctl_common(struct hpet_dev *devp, int cmd, unsigned long arg, int kernel)
{
struct hpet_info info;
info.hi_ireqfreq = hpet_time_div(hpetp,
devp->hd_ireqfreq);
if (devp->hd_ireqfreq)
info.hi_ireqfreq =
hpet_time_div(hpetp, devp->hd_ireqfreq);
else
info.hi_ireqfreq = 0;
info.hi_flags =
readq(&timer->hpet_config) & Tn_PER_INT_CAP_MASK;
info.hi_hpet = devp->hd_hpets->hp_which;