megaraid_sas: Make tape drives visible on PERC5 controllers
The DELL PERC5 controller firmware does not list tape drives in response to MR_DCMD_PD_LIST_QUERY. This causes tape drives not be exposed to the OS when connected to a PERC5 controller. This patch permits detection of tape drives connected to a PERC5 controller by exposing non-TYPE_DISK devices unconditionally. Signed-off-by: Kashyap Desai <kashyap.desai@avagotech.com> Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
parent
f3951a3709
commit
aed335eecf
|
@ -1790,6 +1790,7 @@ struct megasas_instance {
|
|||
u8 UnevenSpanSupport;
|
||||
|
||||
u8 supportmax256vd;
|
||||
u8 allow_fw_scan;
|
||||
u16 fw_supported_vd_count;
|
||||
u16 fw_supported_pd_count;
|
||||
|
||||
|
|
|
@ -1760,6 +1760,20 @@ static void megasas_set_dma_alignment(struct scsi_device *sdev)
|
|||
|
||||
static int megasas_slave_configure(struct scsi_device *sdev)
|
||||
{
|
||||
u16 pd_index = 0;
|
||||
struct megasas_instance *instance;
|
||||
|
||||
instance = megasas_lookup_instance(sdev->host->host_no);
|
||||
if (instance->allow_fw_scan) {
|
||||
if (sdev->channel < MEGASAS_MAX_PD_CHANNELS &&
|
||||
sdev->type == TYPE_DISK) {
|
||||
pd_index = (sdev->channel * MEGASAS_MAX_DEV_PER_CHANNEL) +
|
||||
sdev->id;
|
||||
if (instance->pd_list[pd_index].driveState !=
|
||||
MR_PD_STATE_SYSTEM)
|
||||
return -ENXIO;
|
||||
}
|
||||
}
|
||||
megasas_set_dma_alignment(sdev);
|
||||
/*
|
||||
* The RAID firmware may require extended timeouts.
|
||||
|
@ -1783,9 +1797,8 @@ static int megasas_slave_alloc(struct scsi_device *sdev)
|
|||
pd_index =
|
||||
(sdev->channel * MEGASAS_MAX_DEV_PER_CHANNEL) +
|
||||
sdev->id;
|
||||
if ((instance->pd_list[pd_index].driveState ==
|
||||
MR_PD_STATE_SYSTEM) ||
|
||||
(instance->pd_list[pd_index].driveType != TYPE_DISK)) {
|
||||
if ((instance->allow_fw_scan || instance->pd_list[pd_index].driveState ==
|
||||
MR_PD_STATE_SYSTEM)) {
|
||||
return 0;
|
||||
}
|
||||
return -ENXIO;
|
||||
|
@ -4699,6 +4712,7 @@ static int megasas_init_fw(struct megasas_instance *instance)
|
|||
case PCI_DEVICE_ID_DELL_PERC5:
|
||||
default:
|
||||
instance->instancet = &megasas_instance_template_xscale;
|
||||
instance->allow_fw_scan = 1;
|
||||
break;
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in New Issue