regulator: palmas: Remove wrong comment for the equation calculating num_voltages
Current equation on the comment is wrong. For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1. Since the linear mapping for PALMAS is not all starting from 0, the equation on the comment is not useful and misleading. Thus remove it. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
parent
087d30e304
commit
ae3e101286
|
@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
|
|||
#define SMPS_CTRL_MODE_ECO 0x02
|
||||
#define SMPS_CTRL_MODE_PWM 0x03
|
||||
|
||||
/* These values are derived from the data sheet. And are the number of steps
|
||||
* where there is a voltage change, the ranges at beginning and end of register
|
||||
* max/min values where there are no change are ommitted.
|
||||
*
|
||||
* So they are basically (maxV-minV)/stepV
|
||||
*/
|
||||
#define PALMAS_SMPS_NUM_VOLTAGES 122
|
||||
#define PALMAS_SMPS10_NUM_VOLTAGES 2
|
||||
#define PALMAS_LDO_NUM_VOLTAGES 50
|
||||
|
|
Loading…
Reference in New Issue