platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.
Fixes: 648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
parent
0b43e41e93
commit
ad0d315b4d
|
@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "SIMATIC IPC227E",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
|
||||
},
|
||||
},
|
||||