rcu: Add comments marking transitions between RCU watching and not
It is not as clear as it might be just where in RCU's idle entry/exit code RCU stops and starts watching the current CPU. This commit therefore adds comments calling out the transitions. Reported-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Paul E. McKenney <paulmck@kernel.org>
This commit is contained in:
parent
52b1fc3f79
commit
ac3caf8274
|
@ -238,7 +238,9 @@ void rcu_softirq_qs(void)
|
|||
|
||||
/*
|
||||
* Record entry into an extended quiescent state. This is only to be
|
||||
* called when not already in an extended quiescent state.
|
||||
* called when not already in an extended quiescent state, that is,
|
||||
* RCU is watching prior to the call to this function and is no longer
|
||||
* watching upon return.
|
||||
*/
|
||||
static void rcu_dynticks_eqs_enter(void)
|
||||
{
|
||||
|
@ -251,7 +253,7 @@ static void rcu_dynticks_eqs_enter(void)
|
|||
* next idle sojourn.
|
||||
*/
|
||||
seq = atomic_add_return(RCU_DYNTICK_CTRL_CTR, &rdp->dynticks);
|
||||
/* Better be in an extended quiescent state! */
|
||||
// RCU is no longer watching. Better be in extended quiescent state!
|
||||
WARN_ON_ONCE(IS_ENABLED(CONFIG_RCU_EQS_DEBUG) &&
|
||||
(seq & RCU_DYNTICK_CTRL_CTR));
|
||||
/* Better not have special action (TLB flush) pending! */
|
||||
|
@ -261,7 +263,8 @@ static void rcu_dynticks_eqs_enter(void)
|
|||
|
||||
/*
|
||||
* Record exit from an extended quiescent state. This is only to be
|
||||
* called from an extended quiescent state.
|
||||
* called from an extended quiescent state, that is, RCU is not watching
|
||||
* prior to the call to this function and is watching upon return.
|
||||
*/
|
||||
static void rcu_dynticks_eqs_exit(void)
|
||||
{
|
||||
|
@ -274,6 +277,7 @@ static void rcu_dynticks_eqs_exit(void)
|
|||
* critical section.
|
||||
*/
|
||||
seq = atomic_add_return(RCU_DYNTICK_CTRL_CTR, &rdp->dynticks);
|
||||
// RCU is now watching. Better not be in an extended quiescent state!
|
||||
WARN_ON_ONCE(IS_ENABLED(CONFIG_RCU_EQS_DEBUG) &&
|
||||
!(seq & RCU_DYNTICK_CTRL_CTR));
|
||||
if (seq & RCU_DYNTICK_CTRL_MASK) {
|
||||
|
@ -584,6 +588,7 @@ static void rcu_eqs_enter(bool user)
|
|||
WARN_ON_ONCE(IS_ENABLED(CONFIG_RCU_EQS_DEBUG) &&
|
||||
rdp->dynticks_nesting == 0);
|
||||
if (rdp->dynticks_nesting != 1) {
|
||||
// RCU will still be watching, so just do accounting and leave.
|
||||
rdp->dynticks_nesting--;
|
||||
return;
|
||||
}
|
||||
|
@ -596,7 +601,9 @@ static void rcu_eqs_enter(bool user)
|
|||
rcu_prepare_for_idle();
|
||||
rcu_preempt_deferred_qs(current);
|
||||
WRITE_ONCE(rdp->dynticks_nesting, 0); /* Avoid irq-access tearing. */
|
||||
// RCU is watching here ...
|
||||
rcu_dynticks_eqs_enter();
|
||||
// ... but is no longer watching here.
|
||||
rcu_dynticks_task_enter();
|
||||
}
|
||||
|
||||
|
@ -676,7 +683,9 @@ static __always_inline void rcu_nmi_exit_common(bool irq)
|
|||
if (irq)
|
||||
rcu_prepare_for_idle();
|
||||
|
||||
// RCU is watching here ...
|
||||
rcu_dynticks_eqs_enter();
|
||||
// ... but is no longer watching here.
|
||||
|
||||
if (irq)
|
||||
rcu_dynticks_task_enter();
|
||||
|
@ -751,11 +760,14 @@ static void rcu_eqs_exit(bool user)
|
|||
oldval = rdp->dynticks_nesting;
|
||||
WARN_ON_ONCE(IS_ENABLED(CONFIG_RCU_EQS_DEBUG) && oldval < 0);
|
||||
if (oldval) {
|
||||
// RCU was already watching, so just do accounting and leave.
|
||||
rdp->dynticks_nesting++;
|
||||
return;
|
||||
}
|
||||
rcu_dynticks_task_exit();
|
||||
// RCU is not watching here ...
|
||||
rcu_dynticks_eqs_exit();
|
||||
// ... but is watching here.
|
||||
rcu_cleanup_after_idle();
|
||||
trace_rcu_dyntick(TPS("End"), rdp->dynticks_nesting, 1, atomic_read(&rdp->dynticks));
|
||||
WARN_ON_ONCE(IS_ENABLED(CONFIG_RCU_EQS_DEBUG) && !user && !is_idle_task(current));
|
||||
|
@ -832,7 +844,9 @@ static __always_inline void rcu_nmi_enter_common(bool irq)
|
|||
if (irq)
|
||||
rcu_dynticks_task_exit();
|
||||
|
||||
// RCU is not watching here ...
|
||||
rcu_dynticks_eqs_exit();
|
||||
// ... but is watching here.
|
||||
|
||||
if (irq)
|
||||
rcu_cleanup_after_idle();
|
||||
|
@ -842,9 +856,16 @@ static __always_inline void rcu_nmi_enter_common(bool irq)
|
|||
rdp->dynticks_nmi_nesting == DYNTICK_IRQ_NONIDLE &&
|
||||
READ_ONCE(rdp->rcu_urgent_qs) &&
|
||||
!READ_ONCE(rdp->rcu_forced_tick)) {
|
||||
// We get here only if we had already exited the extended
|
||||
// quiescent state and this was an interrupt (not an NMI).
|
||||
// Therefore, (1) RCU is already watching and (2) The fact
|
||||
// that we are in an interrupt handler and that the rcu_node
|
||||
// lock is an irq-disabled lock prevents self-deadlock.
|
||||
// So we can safely recheck under the lock.
|
||||
raw_spin_lock_rcu_node(rdp->mynode);
|
||||
// Recheck under lock.
|
||||
if (rdp->rcu_urgent_qs && !rdp->rcu_forced_tick) {
|
||||
// A nohz_full CPU is in the kernel and RCU
|
||||
// needs a quiescent state. Turn on the tick!
|
||||
WRITE_ONCE(rdp->rcu_forced_tick, true);
|
||||
tick_dep_set_cpu(rdp->cpu, TICK_DEP_BIT_RCU);
|
||||
}
|
||||
|
|
Loading…
Reference in New Issue