regulator: core: create unlocked version of regulator_set_voltage
The unlocked version will be needed when we start propagating voltage changes to the supply regulators. Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
3a40cfc36b
commit
a9f226bcd9
|
@ -2761,33 +2761,14 @@ static int _regulator_do_set_voltage(struct regulator_dev *rdev,
|
|||
return ret;
|
||||
}
|
||||
|
||||
/**
|
||||
* regulator_set_voltage - set regulator output voltage
|
||||
* @regulator: regulator source
|
||||
* @min_uV: Minimum required voltage in uV
|
||||
* @max_uV: Maximum acceptable voltage in uV
|
||||
*
|
||||
* Sets a voltage regulator to the desired output voltage. This can be set
|
||||
* during any regulator state. IOW, regulator can be disabled or enabled.
|
||||
*
|
||||
* If the regulator is enabled then the voltage will change to the new value
|
||||
* immediately otherwise if the regulator is disabled the regulator will
|
||||
* output at the new voltage when enabled.
|
||||
*
|
||||
* NOTE: If the regulator is shared between several devices then the lowest
|
||||
* request voltage that meets the system constraints will be used.
|
||||
* Regulator system constraints must be set for this regulator before
|
||||
* calling this function otherwise this call will fail.
|
||||
*/
|
||||
int regulator_set_voltage(struct regulator *regulator, int min_uV, int max_uV)
|
||||
static int regulator_set_voltage_unlocked(struct regulator *regulator,
|
||||
int min_uV, int max_uV)
|
||||
{
|
||||
struct regulator_dev *rdev = regulator->rdev;
|
||||
int ret = 0;
|
||||
int old_min_uV, old_max_uV;
|
||||
int current_uV;
|
||||
|
||||
mutex_lock(&rdev->mutex);
|
||||
|
||||
/* If we're setting the same range as last time the change
|
||||
* should be a noop (some cpufreq implementations use the same
|
||||
* voltage for multiple frequencies, for example).
|
||||
|
@ -2835,12 +2816,42 @@ int regulator_set_voltage(struct regulator *regulator, int min_uV, int max_uV)
|
|||
goto out2;
|
||||
|
||||
out:
|
||||
mutex_unlock(&rdev->mutex);
|
||||
return ret;
|
||||
out2:
|
||||
regulator->min_uV = old_min_uV;
|
||||
regulator->max_uV = old_max_uV;
|
||||
mutex_unlock(&rdev->mutex);
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
/**
|
||||
* regulator_set_voltage - set regulator output voltage
|
||||
* @regulator: regulator source
|
||||
* @min_uV: Minimum required voltage in uV
|
||||
* @max_uV: Maximum acceptable voltage in uV
|
||||
*
|
||||
* Sets a voltage regulator to the desired output voltage. This can be set
|
||||
* during any regulator state. IOW, regulator can be disabled or enabled.
|
||||
*
|
||||
* If the regulator is enabled then the voltage will change to the new value
|
||||
* immediately otherwise if the regulator is disabled the regulator will
|
||||
* output at the new voltage when enabled.
|
||||
*
|
||||
* NOTE: If the regulator is shared between several devices then the lowest
|
||||
* request voltage that meets the system constraints will be used.
|
||||
* Regulator system constraints must be set for this regulator before
|
||||
* calling this function otherwise this call will fail.
|
||||
*/
|
||||
int regulator_set_voltage(struct regulator *regulator, int min_uV, int max_uV)
|
||||
{
|
||||
int ret = 0;
|
||||
|
||||
mutex_lock(®ulator->rdev->mutex);
|
||||
|
||||
ret = regulator_set_voltage_unlocked(regulator, min_uV, max_uV);
|
||||
|
||||
mutex_unlock(®ulator->rdev->mutex);
|
||||
|
||||
return ret;
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(regulator_set_voltage);
|
||||
|
|
Loading…