drm/nouveau/fan: handle the cases where we are outside of the linear zone
This fixes a bug where, when temperature is outside of the linear range, fan pwm would be outside of the allowed range ([0, 100]) and could get negative in some cases. It seems like a regression that happened when we re-worked the fan management logic before merging. Tested-by: Ozan Çağlayan <ozancag@gmail.com> Signed-off-by: Martin Peres <martin.peres@labri.fr> Signed-off-by: Ben Skeggs <bskeggs@redhat.com>
This commit is contained in:
parent
93260d3c02
commit
a624bafbf1
|
@ -71,6 +71,13 @@ nouveau_therm_update_linear(struct nouveau_therm *therm)
|
|||
u8 temp = therm->temp_get(therm);
|
||||
u16 duty;
|
||||
|
||||
/* handle the non-linear part first */
|
||||
if (temp < linear_min_temp)
|
||||
return priv->fan->bios.min_duty;
|
||||
else if (temp > linear_max_temp)
|
||||
return priv->fan->bios.max_duty;
|
||||
|
||||
/* we are in the linear zone */
|
||||
duty = (temp - linear_min_temp);
|
||||
duty *= (priv->fan->bios.max_duty - priv->fan->bios.min_duty);
|
||||
duty /= (linear_max_temp - linear_min_temp);
|
||||
|
|
Loading…