docs: hwmon: ibmpowernv: convert to ReST format

Convert ibmpowernv to ReST format, in order to allow it to
be parsed by Sphinx.

Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Mauro Carvalho Chehab 2019-04-17 06:46:19 -03:00 committed by Guenter Roeck
parent 9e929c6745
commit a4710b7219
1 changed files with 19 additions and 12 deletions

View File

@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV
========================
Supported systems:
* Any recent IBM P servers based on POWERNV platform
Author: Neelesh Gupta
@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
Sysfs attributes
----------------
======================= =======================================================
fanX_input Measured RPM value.
fanX_min Threshold RPM for alert generation.
fanX_fault 0: No fail condition
1: Failing fan
fanX_fault - 0: No fail condition
- 1: Failing fan
tempX_input Measured ambient temperature.
tempX_max Threshold ambient temperature for alert generation.
@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its temperature sensors.
1: Enable
0: Disable
- 1: Enable
- 0: Disable
inX_input Measured power supply voltage (millivolt)
inX_fault 0: No fail condition.
1: Failing power supply.
inX_fault - 0: No fail condition.
- 1: Failing power supply.
inX_highest Historical maximum voltage
inX_lowest Historical minimum voltage
inX_enable Enable/disable all voltage sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its voltage sensors.
1: Enable
0: Disable
- 1: Enable
- 0: Disable
powerX_input Power consumption (microWatt)
powerX_input_highest Historical maximum power
@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its power sensors.
1: Enable
0: Disable
- 1: Enable
- 0: Disable
currX_input Measured current (milliampere)
currX_highest Historical maximum current
@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its current sensors.
1: Enable
0: Disable
- 1: Enable
- 0: Disable
energyX_input Cumulative energy (microJoule)
======================= =======================================================