docs: hwmon: ibmpowernv: convert to ReST format
Convert ibmpowernv to ReST format, in order to allow it to be parsed by Sphinx. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
9e929c6745
commit
a4710b7219
|
@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV
|
||||||
========================
|
========================
|
||||||
|
|
||||||
Supported systems:
|
Supported systems:
|
||||||
|
|
||||||
* Any recent IBM P servers based on POWERNV platform
|
* Any recent IBM P servers based on POWERNV platform
|
||||||
|
|
||||||
Author: Neelesh Gupta
|
Author: Neelesh Gupta
|
||||||
|
@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
|
||||||
Sysfs attributes
|
Sysfs attributes
|
||||||
----------------
|
----------------
|
||||||
|
|
||||||
|
======================= =======================================================
|
||||||
fanX_input Measured RPM value.
|
fanX_input Measured RPM value.
|
||||||
fanX_min Threshold RPM for alert generation.
|
fanX_min Threshold RPM for alert generation.
|
||||||
fanX_fault 0: No fail condition
|
fanX_fault - 0: No fail condition
|
||||||
1: Failing fan
|
- 1: Failing fan
|
||||||
|
|
||||||
tempX_input Measured ambient temperature.
|
tempX_input Measured ambient temperature.
|
||||||
tempX_max Threshold ambient temperature for alert generation.
|
tempX_max Threshold ambient temperature for alert generation.
|
||||||
|
@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the
|
||||||
sub-group. In POWER9, this attribute corresponds to
|
sub-group. In POWER9, this attribute corresponds to
|
||||||
each OCC. Using this attribute each OCC can be asked to
|
each OCC. Using this attribute each OCC can be asked to
|
||||||
disable/enable all of its temperature sensors.
|
disable/enable all of its temperature sensors.
|
||||||
1: Enable
|
|
||||||
0: Disable
|
- 1: Enable
|
||||||
|
- 0: Disable
|
||||||
|
|
||||||
inX_input Measured power supply voltage (millivolt)
|
inX_input Measured power supply voltage (millivolt)
|
||||||
inX_fault 0: No fail condition.
|
inX_fault - 0: No fail condition.
|
||||||
1: Failing power supply.
|
- 1: Failing power supply.
|
||||||
inX_highest Historical maximum voltage
|
inX_highest Historical maximum voltage
|
||||||
inX_lowest Historical minimum voltage
|
inX_lowest Historical minimum voltage
|
||||||
inX_enable Enable/disable all voltage sensors belonging to the
|
inX_enable Enable/disable all voltage sensors belonging to the
|
||||||
sub-group. In POWER9, this attribute corresponds to
|
sub-group. In POWER9, this attribute corresponds to
|
||||||
each OCC. Using this attribute each OCC can be asked to
|
each OCC. Using this attribute each OCC can be asked to
|
||||||
disable/enable all of its voltage sensors.
|
disable/enable all of its voltage sensors.
|
||||||
1: Enable
|
|
||||||
0: Disable
|
- 1: Enable
|
||||||
|
- 0: Disable
|
||||||
|
|
||||||
powerX_input Power consumption (microWatt)
|
powerX_input Power consumption (microWatt)
|
||||||
powerX_input_highest Historical maximum power
|
powerX_input_highest Historical maximum power
|
||||||
|
@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the
|
||||||
sub-group. In POWER9, this attribute corresponds to
|
sub-group. In POWER9, this attribute corresponds to
|
||||||
each OCC. Using this attribute each OCC can be asked to
|
each OCC. Using this attribute each OCC can be asked to
|
||||||
disable/enable all of its power sensors.
|
disable/enable all of its power sensors.
|
||||||
1: Enable
|
|
||||||
0: Disable
|
- 1: Enable
|
||||||
|
- 0: Disable
|
||||||
|
|
||||||
currX_input Measured current (milliampere)
|
currX_input Measured current (milliampere)
|
||||||
currX_highest Historical maximum current
|
currX_highest Historical maximum current
|
||||||
|
@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the
|
||||||
sub-group. In POWER9, this attribute corresponds to
|
sub-group. In POWER9, this attribute corresponds to
|
||||||
each OCC. Using this attribute each OCC can be asked to
|
each OCC. Using this attribute each OCC can be asked to
|
||||||
disable/enable all of its current sensors.
|
disable/enable all of its current sensors.
|
||||||
1: Enable
|
|
||||||
0: Disable
|
- 1: Enable
|
||||||
|
- 0: Disable
|
||||||
|
|
||||||
energyX_input Cumulative energy (microJoule)
|
energyX_input Cumulative energy (microJoule)
|
||||||
|
======================= =======================================================
|
||||||
|
|
Loading…
Reference in New Issue