mfd: db8500-prcmu: Supply the pdata_size attribute for db8500-thermal
The MFD subsystem requires drivers to state the size of any platform data passed, or it will fail to assign it to the device. This will culminate in a NULL platform_data attribute and normally a failure to probe() or a kernel Oops. Acked-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
This commit is contained in:
parent
eb696c3181
commit
a3ef0deb0f
|
@ -3095,6 +3095,7 @@ static struct mfd_cell db8500_prcmu_devs[] = {
|
|||
.num_resources = ARRAY_SIZE(db8500_thsens_resources),
|
||||
.resources = db8500_thsens_resources,
|
||||
.platform_data = &db8500_thsens_data,
|
||||
.pdata_size = sizeof(db8500_thsens_data),
|
||||
},
|
||||
};
|
||||
|
||||
|
|
Loading…