HID: sony: Set the Sixaxis cable state correctly

Bit 3 in byte 31 of the Sixaxis report indicates whether the battery is
charging or not charging as opposed to whether or not the cable is plugged in.
As a result, when connected via USB and fully charged, the power_supply status
is wrongly reported as 'Discharging' instead of 'Full'.

Use the battery level value to set the cable state so that the power status
is reported correctly as that seems to be the only reliable way to determine the
cable status on the Sixaxis.

Signed-off-by: Frank Praznik <frank.praznik@oh.rr.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
Frank Praznik 2014-08-29 13:11:52 -04:00 committed by Jiri Kosina
parent ff0c57ac70
commit 9fddd74a23
1 changed files with 2 additions and 1 deletions

View File

@ -935,12 +935,13 @@ static void sixaxis_parse_report(struct sony_sc *sc, __u8 *rd, int size)
if (rd[30] >= 0xee) {
battery_capacity = 100;
battery_charging = !(rd[30] & 0x01);
cable_state = 1;
} else {
__u8 index = rd[30] <= 5 ? rd[30] : 5;
battery_capacity = sixaxis_battery_capacity[index];
battery_charging = 0;
cable_state = 0;
}
cable_state = !(rd[31] & 0x04);
spin_lock_irqsave(&sc->lock, flags);
sc->cable_state = cable_state;