ASoC: samsung: odroid: Fix EPLL frequency values

To prevent incorrect setting of the EPLL the clock frequency
values are changed to exact values as possible to obtain on
the EPLL output with given PLL coefficients.
This patch is required after recent change of the EPLL rate
table by patch
"clk: samsung: exynos5420: The EPLL rate table corrections".

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Sylwester Nawrocki 2017-07-21 18:29:20 +02:00 committed by Mark Brown
parent 5771a8c088
commit 9d154e42a3
1 changed files with 3 additions and 3 deletions

View File

@ -42,17 +42,17 @@ static int odroid_card_hw_params(struct snd_pcm_substream *substream,
switch (params_rate(params)) {
case 32000:
case 64000:
pll_freq = 131072000U;
pll_freq = 131072006U;
break;
case 44100:
case 88200:
case 176400:
pll_freq = 180633600U;
pll_freq = 180633609U;
break;
case 48000:
case 96000:
case 192000:
pll_freq = 196608000U;
pll_freq = 196608001U;
break;
default:
return -EINVAL;