pcmcia: Implement CLKRUN protocol disabling for Ricoh bridges
Currently, "disable_clkrun" yenta_socket module parameter is only implemented for TI CardBus bridges. Add also an implementation for Ricoh bridges that have the necessary setting documented in publicly available datasheets. Tested on a RL5C476II with a Sunrich C-160 CardBus NIC that doesn't work correctly unless the CLKRUN protocol is disabled. Let's also make it clear in its description that the "disable_clkrun" module parameter only works on these two previously mentioned brands of CardBus bridges. Signed-off-by: Maciej S. Szmigiero <mail@maciej.szmigiero.name> Cc: stable@vger.kernel.org Signed-off-by: Dominik Brodowski <linux@dominikbrodowski.net>
This commit is contained in:
parent
1b22dcf6b3
commit
95691e3edd
|
@ -119,6 +119,10 @@
|
|||
#define RL5C4XX_MISC_CONTROL 0x2F /* 8 bit */
|
||||
#define RL5C4XX_ZV_ENABLE 0x08
|
||||
|
||||
/* Misc Control 3 Register */
|
||||
#define RL5C4XX_MISC3 0x00A2 /* 16 bit */
|
||||
#define RL5C47X_MISC3_CB_CLKRUN_DIS BIT(1)
|
||||
|
||||
#ifdef __YENTA_H
|
||||
|
||||
#define rl_misc(socket) ((socket)->private[0])
|
||||
|
@ -156,6 +160,35 @@ static void ricoh_set_zv(struct yenta_socket *socket)
|
|||
}
|
||||
}
|
||||
|
||||
static void ricoh_set_clkrun(struct yenta_socket *socket, bool quiet)
|
||||
{
|
||||
u16 misc3;
|
||||
|
||||
/*
|
||||
* RL5C475II likely has this setting, too, however no datasheet
|
||||
* is publicly available for this chip
|
||||
*/
|
||||
if (socket->dev->device != PCI_DEVICE_ID_RICOH_RL5C476 &&
|
||||
socket->dev->device != PCI_DEVICE_ID_RICOH_RL5C478)
|
||||
return;
|
||||
|
||||
if (socket->dev->revision < 0x80)
|
||||
return;
|
||||
|
||||
misc3 = config_readw(socket, RL5C4XX_MISC3);
|
||||
if (misc3 & RL5C47X_MISC3_CB_CLKRUN_DIS) {
|
||||
if (!quiet)
|
||||
dev_dbg(&socket->dev->dev,
|
||||
"CLKRUN feature already disabled\n");
|
||||
} else if (disable_clkrun) {
|
||||
if (!quiet)
|
||||
dev_info(&socket->dev->dev,
|
||||
"Disabling CLKRUN feature\n");
|
||||
misc3 |= RL5C47X_MISC3_CB_CLKRUN_DIS;
|
||||
config_writew(socket, RL5C4XX_MISC3, misc3);
|
||||
}
|
||||
}
|
||||
|
||||
static void ricoh_save_state(struct yenta_socket *socket)
|
||||
{
|
||||
rl_misc(socket) = config_readw(socket, RL5C4XX_MISC);
|
||||
|
@ -172,6 +205,7 @@ static void ricoh_restore_state(struct yenta_socket *socket)
|
|||
config_writew(socket, RL5C4XX_16BIT_IO_0, rl_io(socket));
|
||||
config_writew(socket, RL5C4XX_16BIT_MEM_0, rl_mem(socket));
|
||||
config_writew(socket, RL5C4XX_CONFIG, rl_config(socket));
|
||||
ricoh_set_clkrun(socket, true);
|
||||
}
|
||||
|
||||
|
||||
|
@ -197,6 +231,7 @@ static int ricoh_override(struct yenta_socket *socket)
|
|||
config_writew(socket, RL5C4XX_CONFIG, config);
|
||||
|
||||
ricoh_set_zv(socket);
|
||||
ricoh_set_clkrun(socket, false);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
|
|
@ -26,7 +26,8 @@
|
|||
|
||||
static bool disable_clkrun;
|
||||
module_param(disable_clkrun, bool, 0444);
|
||||
MODULE_PARM_DESC(disable_clkrun, "If PC card doesn't function properly, please try this option");
|
||||
MODULE_PARM_DESC(disable_clkrun,
|
||||
"If PC card doesn't function properly, please try this option (TI and Ricoh bridges only)");
|
||||
|
||||
static bool isa_probe = 1;
|
||||
module_param(isa_probe, bool, 0444);
|
||||
|
|