thermal/drivers/rzg2l: Fix comments
This patch replaces 'Capture times'->'Total number of ADC data samples' as the former does not really explain much. It also fixes the typo * caliberation->calibration Lastly, as per the coding style /* should be on a separate line. This patch fixes this issue. Reported-by: Pavel Machek <pavel@denx.de> Signed-off-by: Biju Das <biju.das.jz@bp.renesas.com> Link: https://lore.kernel.org/r/20220718121440.556408-1-biju.das.jz@bp.renesas.com Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
This commit is contained in:
parent
11188b4399
commit
8f5a9371e6
|
@ -47,7 +47,7 @@
|
|||
|
||||
#define TS_CODE_AVE_SCALE(x) ((x) * 1000000)
|
||||
#define MCELSIUS(temp) ((temp) * MILLIDEGREE_PER_DEGREE)
|
||||
#define TS_CODE_CAP_TIMES 8 /* Capture times */
|
||||
#define TS_CODE_CAP_TIMES 8 /* Total number of ADC data samples */
|
||||
|
||||
#define RZG2L_THERMAL_GRAN 500 /* milli Celsius */
|
||||
#define RZG2L_TSU_SS_TIMEOUT_US 1000
|
||||
|
@ -80,7 +80,8 @@ static int rzg2l_thermal_get_temp(void *devdata, int *temp)
|
|||
int val, i;
|
||||
|
||||
for (i = 0; i < TS_CODE_CAP_TIMES ; i++) {
|
||||
/* TSU repeats measurement at 20 microseconds intervals and
|
||||
/*
|
||||
* TSU repeats measurement at 20 microseconds intervals and
|
||||
* automatically updates the results of measurement. As per
|
||||
* the HW manual for measuring temperature we need to read 8
|
||||
* values consecutively and then take the average.
|
||||
|
@ -92,16 +93,18 @@ static int rzg2l_thermal_get_temp(void *devdata, int *temp)
|
|||
|
||||
ts_code_ave = result / TS_CODE_CAP_TIMES;
|
||||
|
||||
/* Calculate actual sensor value by applying curvature correction formula
|
||||
/*
|
||||
* Calculate actual sensor value by applying curvature correction formula
|
||||
* dsensor = ts_code_ave / (1 + ts_code_ave * 0.000013). Here we are doing
|
||||
* integer calculation by scaling all the values by 1000000.
|
||||
*/
|
||||
dsensor = TS_CODE_AVE_SCALE(ts_code_ave) /
|
||||
(TS_CODE_AVE_SCALE(1) + (ts_code_ave * CURVATURE_CORRECTION_CONST));
|
||||
|
||||
/* The temperature Tj is calculated by the formula
|
||||
/*
|
||||
* The temperature Tj is calculated by the formula
|
||||
* Tj = (dsensor − calib1) * 165/ (calib0 − calib1) − 40
|
||||
* where calib0 and calib1 are the caliberation values.
|
||||
* where calib0 and calib1 are the calibration values.
|
||||
*/
|
||||
val = ((dsensor - priv->calib1) * (MCELSIUS(165) /
|
||||
(priv->calib0 - priv->calib1))) - MCELSIUS(40);
|
||||
|
@ -122,7 +125,8 @@ static int rzg2l_thermal_init(struct rzg2l_thermal_priv *priv)
|
|||
rzg2l_thermal_write(priv, TSU_SM, TSU_SM_NORMAL_MODE);
|
||||
rzg2l_thermal_write(priv, TSU_ST, 0);
|
||||
|
||||
/* Before setting the START bit, TSU should be in normal operating
|
||||
/*
|
||||
* Before setting the START bit, TSU should be in normal operating
|
||||
* mode. As per the HW manual, it will take 60 µs to place the TSU
|
||||
* into normal operating mode.
|
||||
*/
|
||||
|
@ -217,7 +221,7 @@ static int rzg2l_thermal_probe(struct platform_device *pdev)
|
|||
if (ret)
|
||||
goto err;
|
||||
|
||||
dev_dbg(dev, "TSU probed with %s caliberation values",
|
||||
dev_dbg(dev, "TSU probed with %s calibration values",
|
||||
rzg2l_thermal_read(priv, OTPTSUTRIM_REG(0)) ? "hw" : "sw");
|
||||
|
||||
return 0;
|
||||
|
|
Loading…
Reference in New Issue