[PATCH] Altix snsc: duplicate kobject fix
from: Greg Howard <ghoward@sgi.com> Fix Altix system controller (snsc) device names to include the slot number of the blade whose associated system controller is the target of the device interface. Including the slot number avoids a problem we're currently having where slots within the same enclosure are attempting to create multiple kobjects with identical names. Signed-off-by: Greg Howard <ghoward@sgi.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
parent
5b20192727
commit
8c4335a87c
|
@ -390,7 +390,8 @@ scdrv_init(void)
|
|||
format_module_id(devnamep, geo_module(geoid),
|
||||
MODULE_FORMAT_BRIEF);
|
||||
devnamep = devname + strlen(devname);
|
||||
sprintf(devnamep, "#%d", geo_slab(geoid));
|
||||
sprintf(devnamep, "^%d#%d", geo_slot(geoid),
|
||||
geo_slab(geoid));
|
||||
|
||||
/* allocate sysctl device data */
|
||||
scd = kzalloc(sizeof (struct sysctl_data_s),
|
||||
|
|
Loading…