Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management fixes from Zhang Rui: - Fix a potential deadlock in cpu_cooling driver, which was introduced in 4.11-rc1. (Matthew Wilcox) - Fix the cpu_cooling and devfreq_cooling code to handle possible error return value from OPP calls, together with three minor fixes in the same patch series. (Viresh Kumar) * 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: thermal: cpu_cooling: Check OPP for errors thermal: cpu_cooling: Replace dev_warn with dev_err thermal: devfreq: Check OPP for errors thermal: devfreq_cooling: Replace dev_warn with dev_err thermal: devfreq: Simplify expression thermal: Fix potential deadlock in cpu_cooling
This commit is contained in:
commit
89970a04d7
|
@ -107,8 +107,6 @@ struct cpufreq_cooling_device {
|
|||
};
|
||||
static DEFINE_IDA(cpufreq_ida);
|
||||
|
||||
static unsigned int cpufreq_dev_count;
|
||||
|
||||
static DEFINE_MUTEX(cooling_list_lock);
|
||||
static LIST_HEAD(cpufreq_dev_list);
|
||||
|
||||
|
@ -395,13 +393,20 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_device,
|
|||
|
||||
opp = dev_pm_opp_find_freq_exact(cpufreq_device->cpu_dev, freq_hz,
|
||||
true);
|
||||
if (IS_ERR(opp)) {
|
||||
dev_warn_ratelimited(cpufreq_device->cpu_dev,
|
||||
"Failed to find OPP for frequency %lu: %ld\n",
|
||||
freq_hz, PTR_ERR(opp));
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
voltage = dev_pm_opp_get_voltage(opp);
|
||||
dev_pm_opp_put(opp);
|
||||
|
||||
if (voltage == 0) {
|
||||
dev_warn_ratelimited(cpufreq_device->cpu_dev,
|
||||
"Failed to get voltage for frequency %lu: %ld\n",
|
||||
freq_hz, IS_ERR(opp) ? PTR_ERR(opp) : 0);
|
||||
dev_err_ratelimited(cpufreq_device->cpu_dev,
|
||||
"Failed to get voltage for frequency %lu\n",
|
||||
freq_hz);
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
|
@ -693,9 +698,9 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
|
|||
|
||||
*state = cpufreq_cooling_get_level(cpu, target_freq);
|
||||
if (*state == THERMAL_CSTATE_INVALID) {
|
||||
dev_warn_ratelimited(&cdev->device,
|
||||
"Failed to convert %dKHz for cpu %d into a cdev state\n",
|
||||
target_freq, cpu);
|
||||
dev_err_ratelimited(&cdev->device,
|
||||
"Failed to convert %dKHz for cpu %d into a cdev state\n",
|
||||
target_freq, cpu);
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
|
@ -771,6 +776,7 @@ __cpufreq_cooling_register(struct device_node *np,
|
|||
unsigned int freq, i, num_cpus;
|
||||
int ret;
|
||||
struct thermal_cooling_device_ops *cooling_ops;
|
||||
bool first;
|
||||
|
||||
if (!alloc_cpumask_var(&temp_mask, GFP_KERNEL))
|
||||
return ERR_PTR(-ENOMEM);
|
||||
|
@ -874,13 +880,14 @@ __cpufreq_cooling_register(struct device_node *np,
|
|||
cpufreq_dev->cool_dev = cool_dev;
|
||||
|
||||
mutex_lock(&cooling_list_lock);
|
||||
list_add(&cpufreq_dev->node, &cpufreq_dev_list);
|
||||
|
||||
/* Register the notifier for first cpufreq cooling device */
|
||||
if (!cpufreq_dev_count++)
|
||||
first = list_empty(&cpufreq_dev_list);
|
||||
list_add(&cpufreq_dev->node, &cpufreq_dev_list);
|
||||
mutex_unlock(&cooling_list_lock);
|
||||
|
||||
if (first)
|
||||
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
mutex_unlock(&cooling_list_lock);
|
||||
|
||||
goto put_policy;
|
||||
|
||||
|
@ -1021,6 +1028,7 @@ EXPORT_SYMBOL(of_cpufreq_power_cooling_register);
|
|||
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
||||
{
|
||||
struct cpufreq_cooling_device *cpufreq_dev;
|
||||
bool last;
|
||||
|
||||
if (!cdev)
|
||||
return;
|
||||
|
@ -1028,14 +1036,15 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
|||
cpufreq_dev = cdev->devdata;
|
||||
|
||||
mutex_lock(&cooling_list_lock);
|
||||
list_del(&cpufreq_dev->node);
|
||||
/* Unregister the notifier for the last cpufreq cooling device */
|
||||
if (!--cpufreq_dev_count)
|
||||
last = list_empty(&cpufreq_dev_list);
|
||||
mutex_unlock(&cooling_list_lock);
|
||||
|
||||
if (last)
|
||||
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
|
||||
list_del(&cpufreq_dev->node);
|
||||
mutex_unlock(&cooling_list_lock);
|
||||
|
||||
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
|
||||
ida_simple_remove(&cpufreq_ida, cpufreq_dev->id);
|
||||
kfree(cpufreq_dev->dyn_power_table);
|
||||
|
|
|
@ -186,16 +186,22 @@ get_static_power(struct devfreq_cooling_device *dfc, unsigned long freq)
|
|||
return 0;
|
||||
|
||||
opp = dev_pm_opp_find_freq_exact(dev, freq, true);
|
||||
if (IS_ERR(opp) && (PTR_ERR(opp) == -ERANGE))
|
||||
if (PTR_ERR(opp) == -ERANGE)
|
||||
opp = dev_pm_opp_find_freq_exact(dev, freq, false);
|
||||
|
||||
if (IS_ERR(opp)) {
|
||||
dev_err_ratelimited(dev, "Failed to find OPP for frequency %lu: %ld\n",
|
||||
freq, PTR_ERR(opp));
|
||||
return 0;
|
||||
}
|
||||
|
||||
voltage = dev_pm_opp_get_voltage(opp) / 1000; /* mV */
|
||||
dev_pm_opp_put(opp);
|
||||
|
||||
if (voltage == 0) {
|
||||
dev_warn_ratelimited(dev,
|
||||
"Failed to get voltage for frequency %lu: %ld\n",
|
||||
freq, IS_ERR(opp) ? PTR_ERR(opp) : 0);
|
||||
dev_err_ratelimited(dev,
|
||||
"Failed to get voltage for frequency %lu\n",
|
||||
freq);
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in New Issue