media: rc: ir-rc6-decoder: enable toggle bit for Kathrein RCU-676 remote

The Kathrein RCU-676 remote uses the 32-bit rc6 protocol and toggles
bit 15 (0x8000) on repeated button presses, like MCE remotes.

Add it's customer code 0x80460000 to the 32-bit rc6 toggle
handling code to get proper scancodes and toggle reports.

Signed-off-by: Matthias Reichl <hias@horus.com>
Signed-off-by: Sean Young <sean@mess.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
This commit is contained in:
Matthias Reichl 2018-08-28 09:49:42 -04:00 committed by Mauro Carvalho Chehab
parent 183e19f5b9
commit 85e4af0a7a
1 changed files with 7 additions and 2 deletions

View File

@ -40,6 +40,7 @@
#define RC6_6A_MCE_TOGGLE_MASK 0x8000 /* for the body bits */
#define RC6_6A_LCC_MASK 0xffff0000 /* RC6-6A-32 long customer code mask */
#define RC6_6A_MCE_CC 0x800f0000 /* MCE customer code */
#define RC6_6A_KATHREIN_CC 0x80460000 /* Kathrein RCU-676 customer code */
#ifndef CHAR_BIT
#define CHAR_BIT 8 /* Normally in <limits.h> */
#endif
@ -242,13 +243,17 @@ again:
toggle = 0;
break;
case 32:
if ((scancode & RC6_6A_LCC_MASK) == RC6_6A_MCE_CC) {
switch (scancode & RC6_6A_LCC_MASK) {
case RC6_6A_MCE_CC:
case RC6_6A_KATHREIN_CC:
protocol = RC_PROTO_RC6_MCE;
toggle = !!(scancode & RC6_6A_MCE_TOGGLE_MASK);
scancode &= ~RC6_6A_MCE_TOGGLE_MASK;
} else {
break;
default:
protocol = RC_PROTO_RC6_6A_32;
toggle = 0;
break;
}
break;
default: