media: rc: ir-rc6-decoder: enable toggle bit for Kathrein RCU-676 remote
The Kathrein RCU-676 remote uses the 32-bit rc6 protocol and toggles bit 15 (0x8000) on repeated button presses, like MCE remotes. Add it's customer code 0x80460000 to the 32-bit rc6 toggle handling code to get proper scancodes and toggle reports. Signed-off-by: Matthias Reichl <hias@horus.com> Signed-off-by: Sean Young <sean@mess.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
This commit is contained in:
parent
183e19f5b9
commit
85e4af0a7a
|
@ -40,6 +40,7 @@
|
|||
#define RC6_6A_MCE_TOGGLE_MASK 0x8000 /* for the body bits */
|
||||
#define RC6_6A_LCC_MASK 0xffff0000 /* RC6-6A-32 long customer code mask */
|
||||
#define RC6_6A_MCE_CC 0x800f0000 /* MCE customer code */
|
||||
#define RC6_6A_KATHREIN_CC 0x80460000 /* Kathrein RCU-676 customer code */
|
||||
#ifndef CHAR_BIT
|
||||
#define CHAR_BIT 8 /* Normally in <limits.h> */
|
||||
#endif
|
||||
|
@ -242,13 +243,17 @@ again:
|
|||
toggle = 0;
|
||||
break;
|
||||
case 32:
|
||||
if ((scancode & RC6_6A_LCC_MASK) == RC6_6A_MCE_CC) {
|
||||
switch (scancode & RC6_6A_LCC_MASK) {
|
||||
case RC6_6A_MCE_CC:
|
||||
case RC6_6A_KATHREIN_CC:
|
||||
protocol = RC_PROTO_RC6_MCE;
|
||||
toggle = !!(scancode & RC6_6A_MCE_TOGGLE_MASK);
|
||||
scancode &= ~RC6_6A_MCE_TOGGLE_MASK;
|
||||
} else {
|
||||
break;
|
||||
default:
|
||||
protocol = RC_PROTO_RC6_6A_32;
|
||||
toggle = 0;
|
||||
break;
|
||||
}
|
||||
break;
|
||||
default:
|
||||
|
|
Loading…
Reference in New Issue