[S390] fix syscall restart handling.

If do_signal() gets called several times before returning to user space
and no signal is pending (e.g. cancelled by a debugger) syscall restart
handling could be done several times. This would change the user space
PSW to an address prior to the syscall instruction.
Fix this by making sure that syscall restart handling is only done once.

Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
Heiko Carstens 2006-09-20 15:58:54 +02:00 committed by Martin Schwidefsky
parent 39b083fe1c
commit 8427082a50
1 changed files with 1 additions and 0 deletions

View File

@ -457,6 +457,7 @@ void do_signal(struct pt_regs *regs)
case -ERESTART_RESTARTBLOCK:
regs->gprs[2] = -EINTR;
}
regs->trap = -1; /* Don't deal with this again. */
}
/* Get signal to deliver. When running under ptrace, at this point