thermal: cpu_cooling: initialize 'cpufreq_val' on registration

There is no point checking for validity of 'cpufreq_val' from
cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to
be 0 on the first call but will be valid otherwise.

Lets update it once while the device registers.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
Viresh Kumar 2014-12-04 09:41:59 +05:30 committed by Eduardo Valentin
parent 730abe064b
commit 7adb635b3c
1 changed files with 7 additions and 5 deletions

View File

@ -316,11 +316,6 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
&cpufreq_dev->allowed_cpus))
continue;
if (!cpufreq_dev->cpufreq_val)
cpufreq_dev->cpufreq_val = get_cpu_frequency(
cpumask_any(&cpufreq_dev->allowed_cpus),
cpufreq_dev->cpufreq_state);
max_freq = cpufreq_dev->cpufreq_val;
if (policy->max != max_freq)
@ -444,6 +439,13 @@ __cpufreq_cooling_register(struct device_node *np,
if (!cpufreq_dev)
return ERR_PTR(-ENOMEM);
cpufreq_dev->cpufreq_val = get_cpu_frequency(cpumask_any(clip_cpus), 0);
if (!cpufreq_dev->cpufreq_val) {
pr_err("%s: Failed to get frequency", __func__);
cool_dev = ERR_PTR(-EINVAL);
goto free_cdev;
}
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);