mtd: cfi_cmdset_0002: only check errors when ready in cfi_check_err_status()
Cypress S26K{L|S}P{128|256|512}S datasheet says that the error bits in
the status register are only valid when the "device ready" bit 7 is set.
Add the check for the device ready bit in cfi_check_err_status() as that
function isn't always called with this bit set.
Fixes: 4844ef8030
("mtd: cfi_cmdset_0002: Add support for polling status register")
Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Signed-off-by: Vignesh Raghavendra <vigneshr@ti.com>
This commit is contained in:
parent
03976af89e
commit
72914a8cff
|
@ -136,6 +136,10 @@ static void cfi_check_err_status(struct map_info *map, struct flchip *chip,
|
|||
cfi->device_type, NULL);
|
||||
status = map_read(map, adr);
|
||||
|
||||
/* The error bits are invalid while the chip's busy */
|
||||
if (!map_word_bitsset(map, status, CMD(CFI_SR_DRB)))
|
||||
return;
|
||||
|
||||
if (map_word_bitsset(map, status, CMD(0x3a))) {
|
||||
unsigned long chipstatus = MERGESTATUS(status);
|
||||
|
||||
|
|