mac80211: Fix invalid length passed to IE parser for PLINK CONFIRM frames
The length of the fixed portion of plink confirm frames is 4 bytes longer than the other plink_action frames. This path corrects an error in the length adjustment done for these type of frames. Signed-off-by: Javier Cardona <javier@cozybit.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
57ef5ddb45
commit
70bdb6b275
|
@ -409,7 +409,7 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
|
||||||
baselen = (u8 *) mgmt->u.action.u.plink_action.variable - (u8 *) mgmt;
|
baselen = (u8 *) mgmt->u.action.u.plink_action.variable - (u8 *) mgmt;
|
||||||
if (mgmt->u.action.u.plink_action.action_code == PLINK_CONFIRM) {
|
if (mgmt->u.action.u.plink_action.action_code == PLINK_CONFIRM) {
|
||||||
baseaddr += 4;
|
baseaddr += 4;
|
||||||
baselen -= 4;
|
baselen += 4;
|
||||||
}
|
}
|
||||||
ieee802_11_parse_elems(baseaddr, len - baselen, &elems);
|
ieee802_11_parse_elems(baseaddr, len - baselen, &elems);
|
||||||
if (!elems.peer_link) {
|
if (!elems.peer_link) {
|
||||||
|
|
Loading…
Reference in New Issue