be2net: Fix VLAN promiscous mode for Lancer
To enable VLAN promiscous mode, the HW interface should be created with VLAN promiscous capability in Lancer. Add this capability during creation of the HW interface. Signed-off-by: Padmanabh Ratnakar <padmanabh.ratnakar@emulex.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
af5875bdfe
commit
5d5adb93d0
|
@ -2600,7 +2600,8 @@ static int be_setup(struct be_adapter *adapter)
|
|||
en_flags = BE_IF_FLAGS_UNTAGGED | BE_IF_FLAGS_BROADCAST |
|
||||
BE_IF_FLAGS_MULTICAST | BE_IF_FLAGS_PASS_L3L4_ERRORS;
|
||||
cap_flags = en_flags | BE_IF_FLAGS_MCAST_PROMISCUOUS |
|
||||
BE_IF_FLAGS_PROMISCUOUS;
|
||||
BE_IF_FLAGS_VLAN_PROMISCUOUS | BE_IF_FLAGS_PROMISCUOUS;
|
||||
|
||||
if (adapter->function_caps & BE_FUNCTION_CAPS_RSS) {
|
||||
cap_flags |= BE_IF_FLAGS_RSS;
|
||||
en_flags |= BE_IF_FLAGS_RSS;
|
||||
|
|
Loading…
Reference in New Issue