serial: stm32: correct flow control property spelling
"st,hw-flow-ctrl" property is documented in device tree binding whereas "auto-flow-control" was used in the code. The driver is now aligned with the binding name "st,hw-flow-ctrl". Signed-off-by: Gerald Baeza <gerald.baeza@st.com> Signed-off-by: Alexandre TORGUE <alexandre.torgue@st.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
a14f66a427
commit
59bed2dfe0
|
@ -508,7 +508,7 @@ static struct stm32_port *stm32_of_get_stm32_port(struct platform_device *pdev)
|
|||
return NULL;
|
||||
|
||||
stm32_ports[id].hw_flow_control = of_property_read_bool(np,
|
||||
"auto-flow-control");
|
||||
"st,hw-flow-ctrl");
|
||||
stm32_ports[id].port.line = id;
|
||||
return &stm32_ports[id];
|
||||
}
|
||||
|
|
Loading…
Reference in New Issue