watchdog: sp805: ping fails to abort wdt reset
sp805 wdt asserts interrupt for the first expiry and reloads the counter. If wdt interrupt is set and count reaches zero then wdt reset event is generated. To get wdt reset at 't' timeout the driver loads wdt counter with 't/2'. A ping before time 't' *should* prevent wdt reset. Currently if ping is done after 't/2' then wdt interrupt condition gets set. On the next countdown of loadval wdt reset event occurs eventhough wdt was reloaded before the set timeout 't'. This patch clears the interrupt condition on ping. Signed-off-by: Sandeep Tripathy <tripathy@broadcom.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
This commit is contained in:
parent
29efefb909
commit
55e071779c
|
@ -139,12 +139,11 @@ static int wdt_config(struct watchdog_device *wdd, bool ping)
|
|||
|
||||
writel_relaxed(UNLOCK, wdt->base + WDTLOCK);
|
||||
writel_relaxed(wdt->load_val, wdt->base + WDTLOAD);
|
||||
writel_relaxed(INT_MASK, wdt->base + WDTINTCLR);
|
||||
|
||||
if (!ping) {
|
||||
writel_relaxed(INT_MASK, wdt->base + WDTINTCLR);
|
||||
if (!ping)
|
||||
writel_relaxed(INT_ENABLE | RESET_ENABLE, wdt->base +
|
||||
WDTCONTROL);
|
||||
}
|
||||
|
||||
writel_relaxed(LOCK, wdt->base + WDTLOCK);
|
||||
|
||||
|
|
Loading…
Reference in New Issue