s390/tape: remove redundant if statement
The unit check handler for 3480 / 3490 tapes used to print a different warning message for erpa code 0x57 dependent on the device type. The warning messages have been remove in a cleanup, the if statement is a left over. Remove it. Reported-by: Fraser Brown <mlfbrown@stanford.edu> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
926a7336a7
commit
55b5eb75e7
|
@ -773,13 +773,11 @@ tape_34xx_unit_check(struct tape_device *device, struct tape_request *request,
|
||||||
"occurred\n");
|
"occurred\n");
|
||||||
return tape_34xx_erp_failed(request, -EIO);
|
return tape_34xx_erp_failed(request, -EIO);
|
||||||
case 0x57:
|
case 0x57:
|
||||||
if (device->cdev->id.driver_info == tape_3480) {
|
/*
|
||||||
/* Attention intercept. */
|
* 3480: Attention intercept.
|
||||||
return tape_34xx_erp_retry(request);
|
* 3490: Global status intercept.
|
||||||
} else {
|
*/
|
||||||
/* Global status intercept. */
|
return tape_34xx_erp_retry(request);
|
||||||
return tape_34xx_erp_retry(request);
|
|
||||||
}
|
|
||||||
case 0x5a:
|
case 0x5a:
|
||||||
/*
|
/*
|
||||||
* Tape length incompatible. The tape inserted is too long,
|
* Tape length incompatible. The tape inserted is too long,
|
||||||
|
|
Loading…