of: add notes of critical trips for soctherm
The "critical" type trip in thermal zone can be set to SOC_THERM hardware, it can trigger shut down or reset event from hardware. Signed-off-by: Wei Ni <wni@nvidia.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
c35095215a
commit
4d44cd4ae9
|
@ -26,6 +26,10 @@ Required properties :
|
|||
of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
|
||||
list of valid values when referring to thermal sensors.
|
||||
|
||||
Note:
|
||||
- the "critical" type trip points will be set to SOC_THERM hardware as the
|
||||
shut down temperature. Once the temperature of this thermal zone is higher
|
||||
than it, the system will be shutdown or reset by hardware.
|
||||
|
||||
Example :
|
||||
|
||||
|
@ -51,5 +55,13 @@ Example: referring to thermal sensors :
|
|||
|
||||
thermal-sensors =
|
||||
<&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
|
||||
|
||||
trips {
|
||||
cpu_shutdown_trip: shutdown-trip {
|
||||
temperature = <102500>;
|
||||
hysteresis = <1000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
|