Thermal: do thermal zone update after a cooling device registered
When a new cooling device is registered, we need to update the thermal zone to set the new registered cooling device to a proper state. This fixes a problem that the system is cool, while the fan devices are left running on full speed after boot, if fan device is registered after thermal zone device. Here is the history of why current patch looks like this: https://patchwork.kernel.org/patch/7273041/ CC: <stable@vger.kernel.org> #3.18+ Reference:https://bugzilla.kernel.org/show_bug.cgi?id=92431 Tested-by: Manuel Krause <manuelkrause@netscape.net> Tested-by: szegad <szegadlo@poczta.onet.pl> Tested-by: prash <prash.n.rao@gmail.com> Tested-by: amish <ammdispose-arch@yahoo.com> Reviewed-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Chen Yu <yu.c.chen@intel.com>
This commit is contained in:
parent
ff140fea84
commit
4511f7166a
|
@ -1341,6 +1341,7 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
||||||
if (!result) {
|
if (!result) {
|
||||||
list_add_tail(&dev->tz_node, &tz->thermal_instances);
|
list_add_tail(&dev->tz_node, &tz->thermal_instances);
|
||||||
list_add_tail(&dev->cdev_node, &cdev->thermal_instances);
|
list_add_tail(&dev->cdev_node, &cdev->thermal_instances);
|
||||||
|
atomic_set(&tz->need_update, 1);
|
||||||
}
|
}
|
||||||
mutex_unlock(&cdev->lock);
|
mutex_unlock(&cdev->lock);
|
||||||
mutex_unlock(&tz->lock);
|
mutex_unlock(&tz->lock);
|
||||||
|
@ -1450,6 +1451,7 @@ __thermal_cooling_device_register(struct device_node *np,
|
||||||
const struct thermal_cooling_device_ops *ops)
|
const struct thermal_cooling_device_ops *ops)
|
||||||
{
|
{
|
||||||
struct thermal_cooling_device *cdev;
|
struct thermal_cooling_device *cdev;
|
||||||
|
struct thermal_zone_device *pos = NULL;
|
||||||
int result;
|
int result;
|
||||||
|
|
||||||
if (type && strlen(type) >= THERMAL_NAME_LENGTH)
|
if (type && strlen(type) >= THERMAL_NAME_LENGTH)
|
||||||
|
@ -1494,6 +1496,12 @@ __thermal_cooling_device_register(struct device_node *np,
|
||||||
/* Update binding information for 'this' new cdev */
|
/* Update binding information for 'this' new cdev */
|
||||||
bind_cdev(cdev);
|
bind_cdev(cdev);
|
||||||
|
|
||||||
|
mutex_lock(&thermal_list_lock);
|
||||||
|
list_for_each_entry(pos, &thermal_tz_list, node)
|
||||||
|
if (atomic_cmpxchg(&pos->need_update, 1, 0))
|
||||||
|
thermal_zone_device_update(pos);
|
||||||
|
mutex_unlock(&thermal_list_lock);
|
||||||
|
|
||||||
return cdev;
|
return cdev;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -1826,6 +1834,8 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
|
||||||
tz->trips = trips;
|
tz->trips = trips;
|
||||||
tz->passive_delay = passive_delay;
|
tz->passive_delay = passive_delay;
|
||||||
tz->polling_delay = polling_delay;
|
tz->polling_delay = polling_delay;
|
||||||
|
/* A new thermal zone needs to be updated anyway. */
|
||||||
|
atomic_set(&tz->need_update, 1);
|
||||||
|
|
||||||
dev_set_name(&tz->device, "thermal_zone%d", tz->id);
|
dev_set_name(&tz->device, "thermal_zone%d", tz->id);
|
||||||
result = device_register(&tz->device);
|
result = device_register(&tz->device);
|
||||||
|
@ -1921,7 +1931,9 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
|
||||||
INIT_DELAYED_WORK(&(tz->poll_queue), thermal_zone_device_check);
|
INIT_DELAYED_WORK(&(tz->poll_queue), thermal_zone_device_check);
|
||||||
|
|
||||||
thermal_zone_device_reset(tz);
|
thermal_zone_device_reset(tz);
|
||||||
thermal_zone_device_update(tz);
|
/* Update the new thermal zone and mark it as already updated. */
|
||||||
|
if (atomic_cmpxchg(&tz->need_update, 1, 0))
|
||||||
|
thermal_zone_device_update(tz);
|
||||||
|
|
||||||
return tz;
|
return tz;
|
||||||
|
|
||||||
|
|
|
@ -170,6 +170,7 @@ struct thermal_attr {
|
||||||
* @forced_passive: If > 0, temperature at which to switch on all ACPI
|
* @forced_passive: If > 0, temperature at which to switch on all ACPI
|
||||||
* processor cooling devices. Currently only used by the
|
* processor cooling devices. Currently only used by the
|
||||||
* step-wise governor.
|
* step-wise governor.
|
||||||
|
* @need_update: if equals 1, thermal_zone_device_update needs to be invoked.
|
||||||
* @ops: operations this &thermal_zone_device supports
|
* @ops: operations this &thermal_zone_device supports
|
||||||
* @tzp: thermal zone parameters
|
* @tzp: thermal zone parameters
|
||||||
* @governor: pointer to the governor for this thermal zone
|
* @governor: pointer to the governor for this thermal zone
|
||||||
|
@ -197,6 +198,7 @@ struct thermal_zone_device {
|
||||||
int emul_temperature;
|
int emul_temperature;
|
||||||
int passive;
|
int passive;
|
||||||
unsigned int forced_passive;
|
unsigned int forced_passive;
|
||||||
|
atomic_t need_update;
|
||||||
struct thermal_zone_device_ops *ops;
|
struct thermal_zone_device_ops *ops;
|
||||||
struct thermal_zone_params *tzp;
|
struct thermal_zone_params *tzp;
|
||||||
struct thermal_governor *governor;
|
struct thermal_governor *governor;
|
||||||
|
|