phy: ingenic: Fix a typo in ingenic_usb_phy_probe()
Fix the return value check typo which testing the wrong variable
in ingenic_usb_phy_probe().
Fixes: 31de313dfd
("PHY: Ingenic: Add USB PHY driver using generic PHY framework.")
Reported-by: Hulk Robot <hulkci@huawei.com>
Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Acked-by: Paul Cercueil <paul@crapouillou.net>
Link: https://lore.kernel.org/r/20210305034933.3240914-1-weiyongjun1@huawei.com
Signed-off-by: Vinod Koul <vkoul@kernel.org>
This commit is contained in:
parent
b976c98751
commit
446c200ee3
|
@ -352,8 +352,8 @@ static int ingenic_usb_phy_probe(struct platform_device *pdev)
|
|||
}
|
||||
|
||||
priv->phy = devm_phy_create(dev, NULL, &ingenic_usb_phy_ops);
|
||||
if (IS_ERR(priv))
|
||||
return PTR_ERR(priv);
|
||||
if (IS_ERR(priv->phy))
|
||||
return PTR_ERR(priv->phy);
|
||||
|
||||
phy_set_drvdata(priv->phy, priv);
|
||||
|
||||
|
|