s390/cio: clear timer when terminating driver I/O
When we terminate driver I/O (because we need to stop using a certain channel path) we also need to ensure that a timer (which may have been set up using ccw_device_start_timeout) is cleared. Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
770b55c995
commit
410d5e13e7
|
@ -896,6 +896,7 @@ void ccw_device_kill_io(struct ccw_device *cdev)
|
|||
{
|
||||
int ret;
|
||||
|
||||
ccw_device_set_timeout(cdev, 0);
|
||||
cdev->private->iretry = 255;
|
||||
cdev->private->async_kill_io_rc = -EIO;
|
||||
ret = ccw_device_cancel_halt_clear(cdev);
|
||||
|
|
Loading…