iio: magnetometer: mmc35240: Fix a typo in the name of a constant
Everything is about mmc35240_ except MMC53240_WAIT_SET_RESET (3 and 5 switched). This is likely a typo. Define and use MMC35240_WAIT_SET_RESET instead. Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
b4a339baf3
commit
3f2cde7426
|
@ -53,7 +53,7 @@
|
|||
#define MMC35240_CTRL1_BW_SHIFT 0
|
||||
|
||||
#define MMC35240_WAIT_CHARGE_PUMP 50000 /* us */
|
||||
#define MMC53240_WAIT_SET_RESET 1000 /* us */
|
||||
#define MMC35240_WAIT_SET_RESET 1000 /* us */
|
||||
|
||||
/*
|
||||
* Memsic OTP process code piece is put here for reference:
|
||||
|
@ -225,7 +225,7 @@ static int mmc35240_init(struct mmc35240_data *data)
|
|||
ret = mmc35240_hw_set(data, true);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
usleep_range(MMC53240_WAIT_SET_RESET, MMC53240_WAIT_SET_RESET + 1);
|
||||
usleep_range(MMC35240_WAIT_SET_RESET, MMC35240_WAIT_SET_RESET + 1);
|
||||
|
||||
ret = mmc35240_hw_set(data, false);
|
||||