mmc: sdhci: When a UHS switch fails, cycle power if regulator is used
Power needs to be removed from the card when switching to 1.8v fails. If a regulator is used to control vmmc we need to turn the regulator off and then back on otherwise power will not be removed from the card. Signed-off-by: Philip Rakity <prakity@marvell.com> Reviewed-by: Aaron Lu <aaron.lu@amd.com> Signed-off-by: Chris Ball <cjb@laptop.org>
This commit is contained in:
parent
8a4de07e05
commit
38cfc2f71c
|
@ -1682,11 +1682,15 @@ static int sdhci_do_start_signal_voltage_switch(struct sdhci_host *host,
|
|||
pwr = sdhci_readb(host, SDHCI_POWER_CONTROL);
|
||||
pwr &= ~SDHCI_POWER_ON;
|
||||
sdhci_writeb(host, pwr, SDHCI_POWER_CONTROL);
|
||||
if (host->vmmc)
|
||||
regulator_disable(host->vmmc);
|
||||
|
||||
/* Wait for 1ms as per the spec */
|
||||
usleep_range(1000, 1500);
|
||||
pwr |= SDHCI_POWER_ON;
|
||||
sdhci_writeb(host, pwr, SDHCI_POWER_CONTROL);
|
||||
if (host->vmmc)
|
||||
regulator_enable(host->vmmc);
|
||||
|
||||
pr_info(DRIVER_NAME ": Switching to 1.8V signalling "
|
||||
"voltage failed, retrying with S18R set to 0\n");
|
||||
|
|
Loading…
Reference in New Issue