OMAPDSS: fix warnings if CONFIG_PM_RUNTIME=n
If runtime PM is not enabled in the kernel config, pm_runtime_get_sync() will always return 1 and pm_runtime_put_sync() will always return -ENOSYS. pm_runtime_get_sync() returning 1 presents no problem to the driver, but -ENOSYS from pm_runtime_put_sync() causes the driver to print a warning. One option would be to ignore errors returned by pm_runtime_put_sync() totally, as they only say that the call was unable to put the hardware into suspend mode. However, I chose to ignore the returned -ENOSYS explicitly, and print a warning for other errors, as I think we should get notified if the HW failed to go to suspend properly. Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com> Cc: Jassi Brar <jaswinder.singh@linaro.org> Cc: Grazvydas Ignotas <notasas@gmail.com> Signed-off-by: Archit Taneja <archit@ti.com> Signed-off-by: Florian Tobias Schandinat <FlorianSchandinat@gmx.de>
This commit is contained in:
parent
736f29cd6b
commit
373b436521
|
@ -384,7 +384,7 @@ void dispc_runtime_put(void)
|
|||
DSSDBG("dispc_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&dispc.pdev->dev);
|
||||
WARN_ON(r < 0);
|
||||
WARN_ON(r < 0 && r != -ENOSYS);
|
||||
}
|
||||
|
||||
static inline bool dispc_mgr_is_lcd(enum omap_channel channel)
|
||||
|
|
|
@ -1075,7 +1075,7 @@ void dsi_runtime_put(struct platform_device *dsidev)
|
|||
DSSDBG("dsi_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&dsi->pdev->dev);
|
||||
WARN_ON(r < 0);
|
||||
WARN_ON(r < 0 && r != -ENOSYS);
|
||||
}
|
||||
|
||||
/* source clock for DSI PLL. this could also be PCLKFREE */
|
||||
|
|
|
@ -731,7 +731,7 @@ static void dss_runtime_put(void)
|
|||
DSSDBG("dss_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&dss.pdev->dev);
|
||||
WARN_ON(r < 0 && r != -EBUSY);
|
||||
WARN_ON(r < 0 && r != -ENOSYS && r != -EBUSY);
|
||||
}
|
||||
|
||||
/* DEBUGFS */
|
||||
|
|
|
@ -138,7 +138,7 @@ static void hdmi_runtime_put(void)
|
|||
DSSDBG("hdmi_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&hdmi.pdev->dev);
|
||||
WARN_ON(r < 0);
|
||||
WARN_ON(r < 0 && r != -ENOSYS);
|
||||
}
|
||||
|
||||
static int __init hdmi_init_display(struct omap_dss_device *dssdev)
|
||||
|
|
|
@ -141,7 +141,7 @@ static void rfbi_runtime_put(void)
|
|||
DSSDBG("rfbi_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&rfbi.pdev->dev);
|
||||
WARN_ON(r < 0);
|
||||
WARN_ON(r < 0 && r != -ENOSYS);
|
||||
}
|
||||
|
||||
void rfbi_bus_lock(void)
|
||||
|
|
|
@ -402,7 +402,7 @@ static void venc_runtime_put(void)
|
|||
DSSDBG("venc_runtime_put\n");
|
||||
|
||||
r = pm_runtime_put_sync(&venc.pdev->dev);
|
||||
WARN_ON(r < 0);
|
||||
WARN_ON(r < 0 && r != -ENOSYS);
|
||||
}
|
||||
|
||||
static const struct venc_config *venc_timings_to_config(
|
||||
|
|
Loading…