ieee1394: sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares
Reported by Tino Keitel: PL-3507 with firmware from Prolific does not spin down the disk on START STOP UNIT with power condition = 0 and start = 0. It does however work with power condition = 2 or 3. Also found while investigating this: DViCO Momobay CX-1 and FX-3A (TI TSB42AA9/A based) become unresponsive after START STOP UNIT with power condition = 0 and start = 0. They stay responsive if power condition is set when stopping the motor. Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
This commit is contained in:
parent
ffcaade310
commit
3719122a52
|
@ -186,6 +186,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
|
|||
* - delay inquiry
|
||||
* Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry.
|
||||
*
|
||||
* - power condition
|
||||
* Set the power condition field in the START STOP UNIT commands sent by
|
||||
* sd_mod on suspend, resume, and shutdown (if manage_start_stop is on).
|
||||
* Some disks need this to spin down or to resume properly.
|
||||
*
|
||||
* - override internal blacklist
|
||||
* Instead of adding to the built-in blacklist, use only the workarounds
|
||||
* specified in the module load parameter.
|
||||
|
@ -199,6 +204,8 @@ MODULE_PARM_DESC(workarounds, "Work around device bugs (default = 0"
|
|||
", skip mode page 8 = " __stringify(SBP2_WORKAROUND_MODE_SENSE_8)
|
||||
", fix capacity = " __stringify(SBP2_WORKAROUND_FIX_CAPACITY)
|
||||
", delay inquiry = " __stringify(SBP2_WORKAROUND_DELAY_INQUIRY)
|
||||
", set power condition in start stop unit = "
|
||||
__stringify(SBP2_WORKAROUND_POWER_CONDITION)
|
||||
", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE)
|
||||
", or a combination)");
|
||||
|
||||
|
@ -359,18 +366,25 @@ static const struct {
|
|||
.firmware_revision = 0x002800,
|
||||
.model_id = 0x001010,
|
||||
.workarounds = SBP2_WORKAROUND_INQUIRY_36 |
|
||||
SBP2_WORKAROUND_MODE_SENSE_8,
|
||||
SBP2_WORKAROUND_MODE_SENSE_8 |
|
||||
SBP2_WORKAROUND_POWER_CONDITION,
|
||||
},
|
||||
/* DViCO Momobay FX-3A with TSB42AA9A bridge */ {
|
||||
.firmware_revision = 0x002800,
|
||||
.model_id = 0x000000,
|
||||
.workarounds = SBP2_WORKAROUND_DELAY_INQUIRY,
|
||||
.workarounds = SBP2_WORKAROUND_DELAY_INQUIRY |
|
||||
SBP2_WORKAROUND_POWER_CONDITION,
|
||||
},
|
||||
/* Initio bridges, actually only needed for some older ones */ {
|
||||
.firmware_revision = 0x000200,
|
||||
.model_id = SBP2_ROM_VALUE_WILDCARD,
|
||||
.workarounds = SBP2_WORKAROUND_INQUIRY_36,
|
||||
},
|
||||
/* PL-3507 bridge with Prolific firmware */ {
|
||||
.firmware_revision = 0x012800,
|
||||
.model_id = SBP2_ROM_VALUE_WILDCARD,
|
||||
.workarounds = SBP2_WORKAROUND_POWER_CONDITION,
|
||||
},
|
||||
/* Symbios bridge */ {
|
||||
.firmware_revision = 0xa0b800,
|
||||
.model_id = SBP2_ROM_VALUE_WILDCARD,
|
||||
|
@ -2002,6 +2016,8 @@ static int sbp2scsi_slave_configure(struct scsi_device *sdev)
|
|||
sdev->skip_ms_page_8 = 1;
|
||||
if (lu->workarounds & SBP2_WORKAROUND_FIX_CAPACITY)
|
||||
sdev->fix_capacity = 1;
|
||||
if (lu->workarounds & SBP2_WORKAROUND_POWER_CONDITION)
|
||||
sdev->start_stop_pwr_cond = 1;
|
||||
if (lu->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS)
|
||||
blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);
|
||||
return 0;
|
||||
|
|
|
@ -345,6 +345,7 @@ enum sbp2lu_state_types {
|
|||
#define SBP2_WORKAROUND_FIX_CAPACITY 0x8
|
||||
#define SBP2_WORKAROUND_DELAY_INQUIRY 0x10
|
||||
#define SBP2_INQUIRY_DELAY 12
|
||||
#define SBP2_WORKAROUND_POWER_CONDITION 0x20
|
||||
#define SBP2_WORKAROUND_OVERRIDE 0x100
|
||||
|
||||
#endif /* SBP2_H */
|
||||
|
|
Loading…
Reference in New Issue