ieee1394: sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares

Reported by Tino Keitel:  PL-3507 with firmware from Prolific does not
spin down the disk on START STOP UNIT with power condition = 0 and start
= 0.  It does however work with power condition = 2 or 3.

Also found while investigating this:  DViCO Momobay CX-1 and FX-3A (TI
TSB42AA9/A based) become unresponsive after START STOP UNIT with power
condition = 0 and start = 0.  They stay responsive if power condition is
set when stopping the motor.

Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
This commit is contained in:
Stefan Richter 2008-05-11 00:35:55 +02:00
parent ffcaade310
commit 3719122a52
2 changed files with 19 additions and 2 deletions

View File

@ -186,6 +186,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
* - delay inquiry
* Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry.
*
* - power condition
* Set the power condition field in the START STOP UNIT commands sent by
* sd_mod on suspend, resume, and shutdown (if manage_start_stop is on).
* Some disks need this to spin down or to resume properly.
*
* - override internal blacklist
* Instead of adding to the built-in blacklist, use only the workarounds
* specified in the module load parameter.
@ -199,6 +204,8 @@ MODULE_PARM_DESC(workarounds, "Work around device bugs (default = 0"
", skip mode page 8 = " __stringify(SBP2_WORKAROUND_MODE_SENSE_8)
", fix capacity = " __stringify(SBP2_WORKAROUND_FIX_CAPACITY)
", delay inquiry = " __stringify(SBP2_WORKAROUND_DELAY_INQUIRY)
", set power condition in start stop unit = "
__stringify(SBP2_WORKAROUND_POWER_CONDITION)
", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE)
", or a combination)");
@ -359,18 +366,25 @@ static const struct {
.firmware_revision = 0x002800,
.model_id = 0x001010,
.workarounds = SBP2_WORKAROUND_INQUIRY_36 |
SBP2_WORKAROUND_MODE_SENSE_8,
SBP2_WORKAROUND_MODE_SENSE_8 |
SBP2_WORKAROUND_POWER_CONDITION,
},
/* DViCO Momobay FX-3A with TSB42AA9A bridge */ {
.firmware_revision = 0x002800,
.model_id = 0x000000,
.workarounds = SBP2_WORKAROUND_DELAY_INQUIRY,
.workarounds = SBP2_WORKAROUND_DELAY_INQUIRY |
SBP2_WORKAROUND_POWER_CONDITION,
},
/* Initio bridges, actually only needed for some older ones */ {
.firmware_revision = 0x000200,
.model_id = SBP2_ROM_VALUE_WILDCARD,
.workarounds = SBP2_WORKAROUND_INQUIRY_36,
},
/* PL-3507 bridge with Prolific firmware */ {
.firmware_revision = 0x012800,
.model_id = SBP2_ROM_VALUE_WILDCARD,
.workarounds = SBP2_WORKAROUND_POWER_CONDITION,
},
/* Symbios bridge */ {
.firmware_revision = 0xa0b800,
.model_id = SBP2_ROM_VALUE_WILDCARD,
@ -2002,6 +2016,8 @@ static int sbp2scsi_slave_configure(struct scsi_device *sdev)
sdev->skip_ms_page_8 = 1;
if (lu->workarounds & SBP2_WORKAROUND_FIX_CAPACITY)
sdev->fix_capacity = 1;
if (lu->workarounds & SBP2_WORKAROUND_POWER_CONDITION)
sdev->start_stop_pwr_cond = 1;
if (lu->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS)
blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);
return 0;

View File

@ -345,6 +345,7 @@ enum sbp2lu_state_types {
#define SBP2_WORKAROUND_FIX_CAPACITY 0x8
#define SBP2_WORKAROUND_DELAY_INQUIRY 0x10
#define SBP2_INQUIRY_DELAY 12
#define SBP2_WORKAROUND_POWER_CONDITION 0x20
#define SBP2_WORKAROUND_OVERRIDE 0x100
#endif /* SBP2_H */