OMAP4: PM: TWL6030: fix uv to voltage for >0x39
using 1.35V as a check is not correct, we know that beyond 0x39, voltages are non linear - hence use the conversion iff uV greater than that for 0x39. For example, with 709mV as the smps offset, the max linear is actually 1.41V(0x39vsel)! Signed-off-by: Nishanth Menon <nm@ti.com>
This commit is contained in:
parent
58e241f7be
commit
366494250b
|
@ -134,8 +134,13 @@ static u8 twl6030_uv_to_vsel(unsigned long uv)
|
||||||
* hardcoding only for 1.35 V which is used for 1GH OPP for
|
* hardcoding only for 1.35 V which is used for 1GH OPP for
|
||||||
* OMAP4430.
|
* OMAP4430.
|
||||||
*/
|
*/
|
||||||
|
if (uv > twl6030_vsel_to_uv(0x39)) {
|
||||||
if (uv == 1350000)
|
if (uv == 1350000)
|
||||||
return 0x3A;
|
return 0x3A;
|
||||||
|
pr_err("%s:OUT OF RANGE! non mapped vsel for %ld Vs max %ld\n",
|
||||||
|
__func__, uv, twl6030_vsel_to_uv(0x39));
|
||||||
|
return 0x3A;
|
||||||
|
}
|
||||||
|
|
||||||
if (smps_offset & 0x8)
|
if (smps_offset & 0x8)
|
||||||
return DIV_ROUND_UP(uv - 709000, 12660) + 1;
|
return DIV_ROUND_UP(uv - 709000, 12660) + 1;
|
||||||
|
|