staging: dgap: cleanup duplicated warning message on dgap_tty_init()

If true_count is not same with brd->nasync, warning messages are
printed. But it has duplicated messages within if statement.

Signed-off-by: Daeseok Youn <daeseok.youn@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Daeseok Youn 2014-08-09 14:37:39 +09:00 committed by Greg Kroah-Hartman
parent 274d8b35f8
commit 35edf11bed
1 changed files with 6 additions and 11 deletions

View File

@ -1374,19 +1374,14 @@ static int dgap_tty_init(struct board_t *brd)
brd->nasync = brd->maxports;
if (true_count != brd->nasync) {
if ((brd->type == PPCM) && (true_count == 64)) {
pr_warn("dgap: %s configured for %d ports, has %d ports.\n",
brd->name, brd->nasync, true_count);
pr_warn("dgap: %s configured for %d ports, has %d ports.\n",
brd->name, brd->nasync, true_count);
if ((brd->type == PPCM) &&
(true_count == 64 || true_count == 0)) {
pr_warn("dgap: Please make SURE the EBI cable running from the card\n");
pr_warn("dgap: to each EM module is plugged into EBI IN!\n");
} else if ((brd->type == PPCM) && (true_count == 0)) {
pr_warn("dgap: %s configured for %d ports, has %d ports.\n",
brd->name, brd->nasync, true_count);
pr_warn("dgap: Please make SURE the EBI cable running from the card\n");
pr_warn("dgap: to each EM module is plugged into EBI IN!\n");
} else
pr_warn("dgap: %s configured for %d ports, has %d ports.\n",
brd->name, brd->nasync, true_count);
}
brd->nasync = true_count;