ALSA: aaci: ARM1176 aaci-pl041 AC97 register read timeout
After a reboot on an ARM1176 which amounts to a softreset, it has been noted that the ALSA driver does not get registered and the probe fails with the error "aaci-pl041 fpga:04: ac97 read back fail". In the process of reading from a register the SL1TxBusy bit is set indicating that the transceiver is busy and remains so until the default timeout occurs. Set the Power down register 0x26 to an arbitrary value as specified in the PL041 manual (page: 3-18) so that AACISL1TX/AACISL2TX registers take their default state. Signed-off-by: Philby John <pjohn@in.mvista.com> Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
parent
9c6b8dcefe
commit
29a4f2d31c
|
@ -937,6 +937,7 @@ static int __devinit aaci_probe_ac97(struct aaci *aaci)
|
|||
struct snd_ac97 *ac97;
|
||||
int ret;
|
||||
|
||||
writel(0, aaci->base + AC97_POWERDOWN);
|
||||
/*
|
||||
* Assert AACIRESET for 2us
|
||||
*/
|
||||
|
|
Loading…