opti621: use PCI clock value provided by controller

Use PCI clock value provided by controller instead of depending on
a default (or user supplied) value.

Based on a bugreport from Juergen Kosel & inspired by pata_opti.c code.

Tested-by: Juergen Kosel <juergen.kosel@gmx.de>
Signed-off-by: Bartlomiej Zolnierkiewicz <bzolnier@gmail.com>
This commit is contained in:
Bartlomiej Zolnierkiewicz 2008-06-15 21:00:22 +02:00
parent f361037631
commit 21bd33a656
1 changed files with 22 additions and 20 deletions

View File

@ -193,11 +193,10 @@ typedef struct pio_clocks_s {
int recovery_time; /* Recovery time (clocks) */
} pio_clocks_t;
static void compute_clocks(int pio, pio_clocks_t *clks)
static void compute_clocks(int pio, pio_clocks_t *clks, int bus_speed)
{
if (pio != PIO_NOT_EXIST) {
int adr_setup, data_pls;
int bus_speed = ide_pci_clk ? ide_pci_clk : system_bus_clock();
adr_setup = ide_pio_timings[pio].setup_time;
data_pls = ide_pio_timings[pio].active_time;
@ -234,7 +233,7 @@ static void opti621_set_pio_mode(ide_drive_t *drive, const u8 pio)
u8 pio1 = 0, pio2 = 0;
pio_clocks_t first, second;
int ax, drdy;
u8 cycle1, cycle2, misc;
u8 cycle1, cycle2, misc, clk;
ide_hwif_t *hwif = HWIF(drive);
/* sets drive->drive_data for both drives */
@ -242,8 +241,26 @@ static void opti621_set_pio_mode(ide_drive_t *drive, const u8 pio)
pio1 = hwif->drives[0].drive_data;
pio2 = hwif->drives[1].drive_data;
compute_clocks(pio1, &first);
compute_clocks(pio2, &second);
spin_lock_irqsave(&opti621_lock, flags);
reg_base = hwif->io_ports.data_addr;
/* allow Register-B */
outb(0xc0, reg_base + CNTRL_REG);
/* hmm, setupvic.exe does this ;-) */
outb(0xff, reg_base + 5);
/* if reads 0xff, adapter not exist? */
(void)inb(reg_base + CNTRL_REG);
/* if reads 0xc0, no interface exist? */
read_reg(CNTRL_REG);
/* check CLK speed */
clk = read_reg(STRAP_REG) & 1;
printk(KERN_INFO "%s: CLK = %d MHz\n", hwif->name, clk ? 25 : 33);
compute_clocks(pio1, &first, clk ? 25 : 33);
compute_clocks(pio2, &second, clk ? 25 : 33);
/* ax = max(a1,a2) */
ax = (first.address_time < second.address_time) ? second.address_time : first.address_time;
@ -266,21 +283,6 @@ static void opti621_set_pio_mode(ide_drive_t *drive, const u8 pio)
second.recovery_time, drdy);
#endif
spin_lock_irqsave(&opti621_lock, flags);
reg_base = hwif->io_ports.data_addr;
/* allow Register-B */
outb(0xc0, reg_base + CNTRL_REG);
/* hmm, setupvic.exe does this ;-) */
outb(0xff, reg_base + 5);
/* if reads 0xff, adapter not exist? */
(void)inb(reg_base + CNTRL_REG);
/* if reads 0xc0, no interface exist? */
read_reg(CNTRL_REG);
/* read version, probably 0 */
read_reg(STRAP_REG);
/* program primary drive */
/* select Index-0 for Register-A */
write_reg(0, MISC_REG);