scsi: megaraid_sas: For SRIOV enabled firmware, ensure VF driver waits for 30secs before reset

For SRIOV enabled firmware, if there is a OCR(online controller reset)
possibility driver set the convert flag to 1, which is not happening if
there are outstanding commands even after 180 seconds.  As driver does
not set convert flag to 1 and still making the OCR to run, VF(Virtual
function) driver is directly writing on to the register instead of
waiting for 30 seconds. Setting convert flag to 1 will cause VF driver
will wait for 30 secs before going for reset.

CC: stable@vger.kernel.org
Signed-off-by: Kiran Kumar Kasturi <kiran-kumar.kasturi@broadcom.com>
Signed-off-by: Sumit Saxena <sumit.saxena@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Kashyap Desai 2016-10-21 06:33:29 -07:00 committed by Martin K. Petersen
parent b8aca0c17e
commit 18e1c7f68a
1 changed files with 1 additions and 0 deletions

View File

@ -2823,6 +2823,7 @@ int megasas_wait_for_outstanding_fusion(struct megasas_instance *instance,
dev_err(&instance->pdev->dev, "pending commands remain after waiting, "
"will reset adapter scsi%d.\n",
instance->host->host_no);
*convert = 1;
retval = 1;
}
out: